Chapter 1
Alarm Troubleshooting
Clear the DISCONNECTED Alarm
Restart the CTC application.
Step 1
If the alarm does not clear, log into the Technical Support Website at http://www.cisco.com/techsupport
Step 2
for more information or call Cisco TAC (1-800-553-2447).
1.7.49 DS3-MISM
The DS-3 Frame Format Mismatch condition indicates that a line type format mismatch on a signal
received on the DS-3 port of a 15310-CL-CTX, DS1-28/DS3-EC1-3, or DS1-84/DS3-EC1-3 card. The
condition occurs when the provisioned line type and incoming signal frame format type do no match.
For example, if the line type for a DS-3 port is set to C Bit and the incoming signal line type is detected
as M13, then the port reports a DS3-MISM condition.
Clear the DS3-MISM Condition
In node view, double-click the CTX2500 to display the card view.
Step 1
Click the Provisioning > DS3 > Line tabs.
Step 2
For the row on the appropriate port, verify that the Line Type column is set to match the expected
Step 3
incoming signal (C bit or M13).
If the Line Type field does not match the expected incoming signal, select the correct Line Type in the
Step 4
drop-down list.
Click Apply.
Step 5
If the condition does not clear after the user verifies that the provisioned line type matches the expected
Step 6
incoming signal, use an optical test set to verify that the actual signal coming into the node matches the
expected incoming signal. For specific procedures to use the test set equipment, consult the
manufacturer.
If the condition does not clear, log into the Technical Support Website at
Step 7
http://www.cisco.com/techsupport for more information or call Cisco TAC (1 800 553-2447).
1.7.50 DUP-IPADDR
78-17235-01
Default Severity: Not Alarmed (NA), Non-Service-Affecting (NSA)
SONET Logical Object: DS3
Default Severity: Minor (MN), Non-Service Affecting (NSA)
SONET Logical Object: NE
Cisco ONS 15310-CL and Cisco ONS 15310-MA Troubleshooting Guide, R7.0
1.7.49 DS3-MISM
1-45