1.7.28 AUTOSW-PDI
Clear the AUTOSW-LOP (VT-MON) Alarm
Complete the
Step 1
If the alarm does not clear, log into the Technical Support Website at http://www.cisco.com/techsupport
Step 2
for more information or call Cisco TAC (1 800 553-2447) in order to report a Service-Affecting (SA)
problem.
1.7.28 AUTOSW-PDI
The Automatic Path Protection Switch Caused by Payload Defect Indication (PDI) condition indicates
that automatic path protection switching occurred because of a
protection is configured for revertive switching, it reverts to the working path after the fault clears.
This condition is only reported if the path protection is set up for revertive switching.
Note
Clear the AUTOSW-PDI Condition
Complete the
Step 1
If the condition does not clear, log into the Technical Support Website at
Step 2
http://www.cisco.com/techsupport for more information or call Cisco TAC (1 800 553-2447).
1.7.29 AUTOSW-SDBER
The Automatic Path Protection Switch Caused by Signal Degrade Bit Error Rate (SDBER) condition
indicates that a
the path protection is configured for revertive switching, the path protection reverts to the working path
when the SD-P is resolved.
This condition is only reported if the path protection is set up for revertive switching.
Note
Clear the AUTOSW-SDBER Condition
Complete the
Step 1
Cisco ONS 15310-CL and Cisco ONS 15310-MA Troubleshooting Guide, R7.0
1-30
"Clear the LOP-V Alarm" procedure on page
Default Severity: Not Alarmed (NA), Non-Service-Affecting (NSA)
SONET Logical Object: STSMON
"Clear the PDI-P Condition" procedure on page
Default Severity: Not Alarmed (NA), Non-Service-Affecting (NSA)
Logical Object: STSMON
"SD-P" condition on page 1-125
"Clear the SD-P Condition" procedure on page
Chapter 1
1-93.
"PDI-P" alarm on page
1-115.
caused automatic path protection switching to occur. If
1-126.
Alarm Troubleshooting
1-114. If the path
78-17235-01