LEVELING - SEALING

Proper drainage of the evaporator
condensate water requires the
cabinet to be properly leveled. This
means left to right as well as front
to back.
Silicone Sealant
Floor
Shimming under the cabinet base
frame may level the cabinet. A
slight pitch from front to back is
desirable. The cabinet back should
never be higher than the front.
Once level the cabinet should be
approved material such as General
Electric RTV-102 silicone sealer or
an equivalent.

ACCESS PANEL REMOVAL

The louvered panel on the lower
right front of the cabinet provides
access to the condensing unit and
electrical box.
There is also a back panel that
covers the rear of the condensing
unit compartment that can be
removed to again access to the back
of the compartment. The drain
trap should be filled with water.
This prevents warm air from
migrating back through the drain
to the evaporator coil. Failure to
fill the trap with water, could
result in excessive frosting of the
evaporator coil.
Access to the trap is achieved by
removing the back panel that
covers the rear of the compressor
compartment .
On the LBN-10 this back panel is
a wire grill that allows the
discharge air to flow through the
condensing unit compartment.
Before removing this panel, make
sure the power supply to cabinet is
disconnected.

COMPRESSOR

The compressor is banded for
shipping. Remove the two bolts
holding the compressor bar in
place, then you can pull out the
condensing unit.
Cut the steel band, which holds
down the compressor during
shipping. The compressor should
now float freely on the mounting
springs. DO NOT LOOSEN NUTS.

ELECTRICAL CONNECTIONS

The LBN-4, 5, 6, 7 and 8 models
have a power cord attached to the
unit with a ground prong. Do not
remove the grounding prong under
any circumstances. The cord is
rated 115v/15 amp. The LBN-7,