INSTALLATION and
START UP
LOCATION –
The location of your cabinet is important.
Make sure your selected location is NOT
in any of the following areas as it could
seriously affect the operation.
Not in direct sunlight.
Not in the air path of heat or air
conditioning ducts.
Not at an exit or entrance affected by
extreme temperature change.
Allow 2 feet of clearance at the rear of the
case to allow adequate air movement
across
the
condenser
refrigeration system performance, do not
obstruct the grille at the rear intake and
discharge. If desired, the blank off panel
behind the front (customer side) louvered
panel – may be removed for rear air
intake and front air discharge, but then
insure 2 feet of unobstructed clearance is
left at the case front.
Level case front to back and end to end,
shimming
where
installation to assure proper operating
drains, and refrigeration system.
POWER REQUIREMENTS –
The DC models are equipped with a
three-wire grounded service core for your
protection. The cabinets are designed to
operate
on
115V
current.
A
separate
recommended to prevent product loss due
to overloading or malfunction of other
for
proper
necessary
upon
single-phase
60hz
circuit
is
equipment on the same circuit.
time delay fuse or circuit breaker. The
supply circuit must be properly grounded
and conform to National and Local
Electrical Codes. Voltage, as measured at
the
compressor
operation, must not vary more than 5%
from cabinet serial plate rating. If a low
voltage condition exists, contact your
electrician or power company.
A wiring diagram is provided on the
condenser shroud for each unit.
A power (ON-OFF) switch is provided on
each model.
The switch is accessible
through
a hole provided in the rear
(operator side) access panel
START UP PROCEDURE -
Cut
the
band
compressor in place during shipment.
Make sure fan turns freely. Check for
any connections or parts that might
have loosened during shipment.
Start cabinet, and allow temperature
to pull down to normal level before
loading product.
5
Use a
terminals
during
which
holds
the

Hide quick links:

Advertisement

Table of Contents
loading