Low Battery Alarm; Temp Alarm; Off Course Alarm; Arrival Alarm - Humminbird 787C2 Operation Manual

700 series
Hide thumbs Also See for 787C2:
Table of Contents

Advertisement

531476-1_A - 787c2_Eng.qxd
11/22/2005

Low Battery Alarm

Low Battery Alarm sounds when the input battery
voltage is equal to or less than the menu setting. The battery alarm will only sound for
the battery that is connected to the 700 Series™ Fishing System. The Low Battery Alarm
should be set to warn you when the battery voltage drops below the safety margin that
you have determined. For instance, if you are running a trolling motor (battery
operated), you would want to set the Low Battery Alarm to sound before the battery
voltage drops too low for it to be used to start your main, gasoline-powered engine.
To change the Low Battery Alarm setting:
1. Highlight Low Battery Alarm on the Alarms main menu.
2. Use the LEFT or RIGHT 4-WAY Cursor Control keys to change the Low Battery
Alarm setting. (Off, 8.5V - 13.5V, Default = Off)

Temp Alarm

Temp Alarm sounds when the water temperature
detected by the 700 Series™ reaches the Temp Alarm setting, which is either set in
degrees Fahrenheit or Celsius [International Models only]. For example, if the Temp
Alarm is set to 58 degrees Fahrenheit, and the water temperature falls from 60 degrees
to 58 degrees, the Temp Alarm will sound. Similarly, if the water temperature rises from
56 degrees to 58 degrees, the Temp Alarm will also sound.
To change the Temp Alarm setting:
1. Highlight Temp Alarm on the Alarms main menu.
2. Use the LEFT or RIGHT 4-Way Cursor Control keys to change the Temp Alarm
setting. (Off, 33-120 [Fahrenheit], 0-50 [Celsius], Default = Off)
3:21 AM
Page 96
89

Off Course Alarm

Off Course Alarm sounds when the boat has moved
too far off course based on the menu setting when navigating. Off Course Alarm
allows you to set how far the boat is allowed to move off course before the Off
Course Alarm will sound.
Off Course Limits
Arrival Alarm Circle
To change the Off Course Alarm setting:
1. Highlight Off Course Alarm on the Alarms main menu.
2. Use the LEFT or RIGHT 4-WAY Cursor Control keys to change the Off Course Alarm
setting. (Off, 25 to 3000 feet, 10 to 1000 meters [International Models only],
Default = 300 ft, 100 m)

Arrival Alarm

Arrival Alarm sounds when the boat has either
exceeded the distance to the destination waypoint, or has entered the Arrival Alarm
Circle, based on the menu setting when navigating. Arrival Alarm allows you to set how
close the boat must be to the destination waypoint before the Arrival Alarm will sound.
To change the Arrival Alarm setting:
1. Highlight Arrival Alarm on the Alarms main menu.
2. Use the LEFT or RIGHT 4-WAY Cursor Control keys to change the Arrival Alarm
setting. (Off, 25 to 3000 feet, 10 to 1000 meters [International Models only],
Default = 150 ft, 50 m)
90

Advertisement

Table of Contents
loading

This manual is also suitable for:

700 series