Introduction

Overview

1.1 Overview
The PW6K1R1E reader interface provides a network connected, single door with
paired reader, PoE based solution to the OEM integrator for interfacing TTL/
Wiegand/RS-485 type readers to door hardware. The on-board twisted pair Ethernet
jack with PoE support enables easy installation.
A maximum of 16 PW6K1R1E downstream boards can be connected to PW6K1ICE
controller board.
You can control one physical barrier with PW6K1R1E, using single or paired readers.
The first reader port can accommodate a read head that utilizes Wiegand, magnetic
stripe, or 2-wire RS-485 electrical signaling standards, one or two wire LED controls,
and buzzer control (one wire LED mode only).
The second reader port can accommodate a read head that utilizes Wiegand or
magnetic stripe signaling, one or two wire LED controls, and buzzer control (one wire
LED mode only).
You can use two form-C relay outputs for door strike control or alarm signaling.The
relay contacts are rated at 5A @ 30VAC/DC, dry contact configuration. Four inputs
are provided for monitoring the door contacts, exit push buttons, and alarm contacts.
The PW6K1R1E requires power from PoE or local 12VDC. The reader power should
be based on peak reader power consumption.
The PW6K1R1E may be mounted in a 3-gang switch box; a mounting plate is
supplied with the unit. The PW6K1R1E may be mounted in an enclosure; the supplied
mounting plate has mounting holes that match the MR50 mounting footprint. Refer to
Additional Mounting Information (p. -15) for UL enclosure requirements.
The PW6K1R1E has to be installed on the same subnet as PW6101 (i.e., PW6K1ICE)
or PW6000. The encryption between both PW6000 and PW6K1ICE, and, PW6101
and PW6K1ICE, is built-in and automatic.

1.2 General UL-Compliance

A UL-compliant installation requires the following:
• The PW6K1R1E board must be installed within the protected area.
• The PW6K1R1E board is installed for indoor use only.
• The PW6K1R1E board must be installed with a tamper switch mounted to the
• The fail secure locking mechanism shall only be installed where is is allowed
The PW6K1R1E board is not UL Listed for burglary installations.
Note:
2
www.honeywell.com
enclosure cover.
by the local authority having jurisdiction (AHJ), and it shall not impair the
operation of panic hardware and emergency egress.