8. Final Checklist

1) Is the icemaker level?
2) Is the icemaker in a site where the ambient temperature is within +45°F to +100°F and
the water temperature within +45°F to +90°F all year around?
3) Is there at least 6" clearance at rear and sides and 24" at top for maintenance or
service?
4) Have all shipping carton, tape(s) and packing been removed from the icemaker?
5) Are all components, fasteners and thumbscrews securely in place?
6) Have all electrical and piping connections been made?
7) Has the power supply voltage been checked or tested against the nameplate rating and
the correct voltage selected? And has a proper ground been installed in the icemaker?
8) Are the water supply line shut-off valve and drain valve installed? Has the water
supply pressure been checked to ensure a minimum of 10 PSIG and a maximum of
113 PSIG?
Note: The icemaker may stop running when the water supply is OFF, or if the pressure
is below 10 PSIG. When the proper water pressure is reached, the icemaker
automatically starts running again.
9) Have the compressor hold-down bolts and refrigerant lines been checked against
vibration and possible failure?
10) Has the bin control switch been checked for correct operation? Move the actuator
located on the top of the chute. The compressor should stop in 6 seconds, and the gear
motor in 6 seconds.
11) Has the end user been given the instruction manual, and instructed on how to operate
the icemaker and the importance of the recommended periodic maintenance?
12) Has the end user been given the name and telephone number of an authorized service
agent?
13) Has the warranty tag been filled out and forwarded to the factory for warranty
registration?