[e] Stacking Condenser Unit

1) Secure the lower condenser unit to the legs
with eight bolts (not included).
2) Attach the upper condenser unit on the top of
the lower.
3) Secure the upper condenser unit with the four
screws provided.
4) Install refrigerant lines, and make electrical
connection for each fan motor as shown in
Items [c] and [d].

7. Water Supply and Drain Connections

- See Fig. 9
• External filters, strainers or softeners may be required depending on the water quality.
• Water supply inlet is 1/2" female pipe thread (FPT).
Note: On water-cooled model, two water supply inlets are provided. One is
for ice making water, and the other is for cooling water.
• A water supply line shut-off valve and drain valve should be installed. A minimum of 3/8"
OD copper tubing is recommended for the water supply lines.
• Water supply pressure should be a minimum of 10 PSIG and a maximum of 113 PSIG. If
the pressure exceeds 113 PSIG, the use of a pressure reducing valve is required.
• Drain outlet for icemaking is 3/4" FPT. The icemaker drain and the condenser drain
piping connections must be made separately from the bin drain.
Note: On water-cooled model, a 3/8" FPT is provided for the cooling water outlet.
• The drains must have 1/4" fall per foot on horizontal runs to get a good flow.
• The drains should not be piped directly to the sewer system. An air gap of a minimum of
2 vertical inches should be between the end of the drain pipe from the icemaker or the ice
bin and the floor drain.
• A plumbing permit and services of a licensed plumber may be required in some areas.
• In some areas, a back flow preventer may be required in the cooling water circuit.
Fig. 8