6. Installation of Remote Condenser Unit

[a] Checks Before Installation

1) Unpack and remove shipping carton, tape(s) and packing.
2) Check that the refrigerant lines do not rub or touch lines or other surfaces, and that
the fan blade turns freely.
3) Make sure that the icemaker, line sets and remote condenser unit all use R-404A
refrigerant.

[b] Location

The condenser unit must be positioned in a permanent site under the following
guidelines.
• A firm and flat site.
• A dry and well ventilated area with 24" clearance on both front and rear for ease of
maintenance and service should they be required.
• Normal condenser ambient temperature: -20°F to +122°F. Temperatures not within this
operating range may affect the production capacity of the icemaker.
• The maximum line length for the standard refrigerant charge is 66 feet. Should an
installation require a longer line length, please call 1-800-233-1940 for
recommendations concerning the correct additional refrigerant charge to be added.
Note: If the recommended guidelines of the installation are exceeded, the icemaker
performance may be reduced.