Greenheck DC Installation, Operation And Maintenance Manual page 10

High volume, low speed ceiling fans
Table of Contents

Advertisement

Motor/Hub to Downtube Installation
Components required from Bag # 916399:
• Motor/Hub Assembly (1)
• 3/8 in. – 16 x 2-1/2 in. Grade 8 Hex Bolt (2)
Hardware/Tools Needed (Not Included):
• 9/16 in. Socket
• Socket Wrench
• Torque Wrench
• Phillips Screwdriver
• Lifting Equipment
• Level
• Cribbing (optional)
• Awl (optional)
DANGER
Always disconnect, lock and tag power source before
installing or servicing. Failure to disconnect power
source can result in fire, shock or serious injury.
DANGER
Pour écarter les risques d'incendie, de choc électrique
ou de blessure grave, veiller à toujours débrancher,
verrouiller et étiqueter la source de courant avant
l'installation ou l'entretien.
1. Using a scissor lift or other suitable lifting device,
lift the motor/hub assembly by resting the motor
struts on the lift structure or cribbing.
2. Feed the safety retention cable that is attached to
the motor/hub assembly up through the bottom
of the downtube until the loose end of the safety
cable is accessible at the top of the downtube. Pull
the loose end of the safety retention cable from the
top of the downtube until all of the slack is pulled
through.
3. Using a Phillips screwdriver, remove the front and
back VFD covers and set aside.
4. Carefully align the motor axle with the downtube
opening, making sure that the wires protruding
from the motor axle are on the same side as the
exposed circuit board of the VFD.
3/8 in. - 16 X 2-1/2 in. GRADE 8 HEX BOLT
MOTOR SAFETY CABLE
MOTOR/HUB ASSEMBLY
MOTOR STRUT
10
High Volume, Low Speed Ceiling Fans
IMPORTANT: Do not allow safety cable or wiring to
be crushed while lifting the motor/hub assembly into
the downtube. Safety cable must be kept taut inside
the downtube in order to prevent damage. If either
the safety cable or the wiring are damaged during
installation, contact your local rep or the manufacturer.
NOTE: When leveling the fan, the level should be moved
around the circumference of the downtube periodically
to ensure that the fan is level.
3/8 in. - 16 GRADE 5 NYLON LOCKNUT
REAR VFD COVER
TORQUE TO 33 FT LBF
(44.75 N m)
LIGHT EXTENSION CABLE
(OPTIONAL)
5. Slowly lift the motor/hub assembly until the motor
axle is nested inside the downtube. Take care
to align the motor axle holes with the downtube
holes.
6. Install the supplied (2) 3/8 in. – 16 x 2-1/2 in. grade
8 hex bolts into the locknuts attached to the
downtube. Torque the bolts to a value of 33 ft∙lbf
(44.75 N∙m).
7. Place a level against the downtube and adjust the
angle of the downtube until the fan is level. Tighten
the hardware connecting the downtube to the
mount and torque to 25 ft∙lbf (33.90 N∙m).
8. Plug in the motor power, ground, and hall
connection wires as shown below. Note that the
connectors on the hall connection and motor
power wires only fit in one specific orientation.
1
MOTOR POWER
2
MOTOR GROUND
1
MOTOR POWER
2
MOTOR GROUND
3
HALL CONNECTION
TORQUE TO 25 FT LBF
(33.90 N m)
TORQUE TO 25 FT LBF
(33.90 N m)
3/8 in. - 16 x 1 in. GRADE 5 HEX BOLT
UNIVERSAL MOUNTING BRACKET
DOWNTUBE ASSEMBLY
3
HALL CONNECTION
NOTE:
HALL CABLE PLUG HAS BUILT-IN
ALIGNMENT TAB. DO NOT FORCE
THIS PLUG.
®

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dc-5

Table of Contents