Lincoln Electric POWER MIG 211i Operator's Manual page 22

Table of Contents

Advertisement

POWER MIG 211i
®
PROBLEMS
(SYMPTOMS)
Arc is unstable - Poor starting.
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
Observe all Safety Guidelines detailed throughout this manual
POSSIBLE
1. Check for correct input voltage
to machine.
2. Check for proper electrode
polarity for process.
3. Check gun tip for wear or
damage and proper size -
Replace.
4. Check for proper gas and flow
rate for process. (For MIG
only.)
5. Check work cable for loose or
faulty connections.
6. Check gun for damage or
breaks.
7. Check for proper drive roll ori-
entation and alignment.
8. Check liner for proper size.
CAUSE
If all recommended possible areas of
misadjustment have been checked
and the problem persists, Contact
your local Lincoln Authorized
Field Service Facility.
CAUTION
23
TROUBLE SHOOTING
RECOMMENDED
COURSE OF ACTION

Advertisement

Table of Contents
loading

Table of Contents