Lennox DAVE SIGNATURE SL280DFV Installation Instructions Manual page 35

Gas furnace downflow air discharge
Hide thumbs Also See for DAVE SIGNATURE SL280DFV:
Table of Contents

Advertisement

BLOWER DATA
SL280DF090V60C BLOWER PERFORMANCE (less filter)
0 through 0.8 in. w.g. (Heating) and 0 through 1.0 in. w.g. (Cooling) External Static Pressure Range
Heating Speed
1
DIP Switch Settings
+24%
+18%
+12%
+6%
Factory Default
–6%
–12%
–18%
Cooling Speed
1
DIP Switch Settings
Low
+
1125
Factory Default
1020
900
Cooling and heating speeds are based on a combination of DIP switch settings on the furnace control. Refer to Installation Instructions for specific DIP Switch Settings.
1
Factory default setting.
2
NOTES - The effect of static pressure is included in air volumes shown.
First stage HEAT is approximately 91% of the same second stage HEAT.
First stage COOL (two-stage air conditioning units only) is approximately 70% of the same second stage COOL speed position.
Continuous Fan Only speed is selectable at 28% and 38% of the selected second stage cooling speed - minimum 450 cfm.
Lennox iHarmony
Zoning System Applications - Minimum blower speed is 450 cfm.
®
BLOWER DATA
SL280DF110V60C BLOWER PERFORMANCE (less filter)
0 through 0.8 in. w.g. (Heating) and 0 through 1.0 in. w.g. (Cooling) External Static Pressure Range
Heating Speed
1
DIP Switch Settings
+24%
+18%
+12%
+6%
Factory Default
–6%
–12%
–18%
Cooling Speed
1
DIP Switch Settings
Low
+
1055
Factory Default
975
895
Cooling and heating speeds are based on a combination of DIP switch settings on the furnace control. Refer to Installation Instructions for specific DIP Switch Settings.
1
Factory default setting.
2
NOTES - The effect of static pressure is included in air volumes shown.
First stage HEAT is approximately 91% of the same second stage HEAT.
First stage COOL (two-stage air conditioning units only) is approximately 70% of the same second stage COOL speed position.
Continuous Fan Only speed is selectable at 28% and 38% of the selected second stage cooling speed - minimum 450 cfm.
Lennox iHarmony
Zoning System Applications - Minimum blower speed is 450 cfm.
®
First Stage Heating Speed - cfm
1540
1465
1390
1320
1245
1170
1095
1020
First Stage Cooling Speed - cfm
Medium-Low
Medium-High
1250
1400
1135
1285
1005
1155
First Stage Heating Speed - cfm
1645
1565
1485
1405
1325
1245
1170
1090
First Stage Cooling Speed - cfm
Medium-Low
Medium-High
1230
1365
1115
1250
1005
1130
HEATING
COOLING
Second Stage Cooling Speed - cfm
High
Low
2
1590
1585
1445
1420
1280
1305
HEATING
COOLING
Second Stage Cooling Speed - cfm
High
Low
2
1525
1500
1400
1360
1245
1225
Page 35
Second Stage Heating Speed - cfm
1695
1615
1530
1450
1365
1285
1205
1120
Medium-Low
Medium-High
1770
2000
1610
1845
1395
1645
Second Stage Heating Speed - cfm
1810
1720
1635
1545
1460
1370
1285
1195
Medium-Low
Medium-High
1755
1915
1585
1770
1405
1595
High
2
2275
2,050
1875
High
2
2120
1960
1760