Lennox DAVE SIGNATURE SL280DFV Installation Instructions Manual page 17

Gas furnace downflow air discharge
Hide thumbs Also See for DAVE SIGNATURE SL280DFV:
Table of Contents

Advertisement

Height
Lateral
H
L
(feet)
(feet)
1
6
2
3
1
8
2
3
1
10
2
3
1
15
2
3
1
20
2
3
1
30
2
3
Vent
Height
4 inch
H
(feet)
FAN + FAN
6
92
8
101
10
110
15
125
20
136
30
152
Vent Connector Capacity
Type B Double-Wall Vents with Type B Double-Wall Connectors
Serving Two or More Category I Appliances
3 inch
Appliance Input Rating in Thousands of Btu Per Hour
Min
Max
Min
22
37
23
41
24
44
22
40
23
44
24
47
22
43
23
47
24
50
21
50
22
53
24
55
21
54
2
57
23
60
20
62
21
64
22
66
Common Vent Capacity
Type B Double-Wall Vents with Type B Double-Wall Connectors
Serving Two or More Category I Appliances
Vent and Connector Diameter - D (inches)
5 inch
Appliance Input Rating in Thousands of Btu Per Hour
FAN + NAT
FAN + FAN
81
140
90
155
97
169
112
195
123
215
138
244
TABLE 6
Vent and Connector Diameter - D (inches)
4 inch
Max
Min
35
66
37
75
38
81
35
72
36
80
51
37
87
53
34
78
49
36
86
51
37
92
52
33
89
47
35
96
49
36
102
51
33
99
46
34
105
48
35
110
50
31
113
45
33
118
47
34
123
48
TABLE 7
FAN + NAT
FAN + FAN
116
204
129
224
141
243
164
283
183
314
210
361
Page 17
5 inch
Max
Min
46
106
58
48
121
60
49
132
62
49
114
64
128
66
139
67
123
65
136
67
146
69
142
64
153
66
163
68
157
62
167
64
176
66
181
60
190
62
198
64
7 inch
FAN + NAT
FAN + FAN
161
309
178
339
194
367
228
427
255
475
297
547
6 inch
Max
164
183
199
176
195
210
189
206
220
220
235
248
246
259
271
288
299
309
7 inch
FAN + NAT
248
275
299
352
394
459