Lennox DAVE SIGNATURE SL280DFV Installation Instructions Manual page 19

Gas furnace downflow air discharge
Hide thumbs Also See for DAVE SIGNATURE SL280DFV:
Table of Contents

Advertisement

Nominal
Internal
Iron Pipe
Diameter
Size Inches
inches
(mm)
(mm)
1/2
.622
(12.7)
(17.799)
3/4
.824
(19.05)
(20.930)
1
1.049
(25.4)
(26.645)
1-1/4
1.380
(31.75)
(35.052)
1-1/2
1.610
(38.1)
(40.894)
2
2.067
(50.8)
(52.502)
2-1/2
2.469
(63.5)
(67.713)
3
3.068
(76.2)
(77.927)
NOTE - Capacity given in cubic feet (m3 ) of gas per hour and based on 0.60 specific gravity gas.
MANUAL
MAIN SHUT-OFF
VALVE
GROUND
JOINT
UNION
DRIP LEG
Leak Check
After gas piping is completed, carefully check all field-in-
stalled piping connections for gas leaks. Use a commer-
cially available leak detecting solution specifically manu-
factured for leak detection. Never use an open flame to
test for gas leaks.
NOTE - If emergency shutoff is necessary, shut off the
main manual gas valve and disconnect the main power
to the furnace. The installer should properly label these
devices.
Gas Pipe Capacity - ft3/hr (m3/hr)
10
20
30
(3.048)
(6.096)
(9,144)
172
118
95
(4.87)
(3.34)
(2.69)
360
247
199
(10.19)
(7.000)
(5.63)
678
466
374
(19.19)
(13.19)
(10.59)
1350
957
768
(38.22)
(27.09)
(22.25)
2090
1430
1150
(59.18)
(40.49)
(32.56)
4020
2760
2220
(113.83)
(78.15)
(62.86)
6400
4400
3530
(181.22)
(124.59)
(99.95)
11300
7780
6250
(319.98)
(220.30)
(176.98)
Left Side Piping
(Standard)
AUTOMATIC
GAS VALVE
(with manual
shut-off valve)
NOTE - BLACK IRON PIPE ONLY TO BE ROUTED INSIDE OF CABINET
TABLE 8
Length of Pipe - feet (m)
40
50
60
(12,192)
(15.240)
(18.288)
81
72
65
(2.29)
(2.03)
(1.84)
170
151
137
(4.81)
(4.23)
(3.87)
320
284
257
(9.06)
(8.04)
(7.27)
657
583
528
(18.60)
(16.50)
(14.95)
985
873
791
(27.89)
(24.72)
(22.39)
1900
1680
1520
(53.80)
(47.57)
(43.04)
3020
2680
2480
(85.51)
(75.88)
(70.22)
5350
4740
4290
(151.49)
(134.22)
(121.47)
AUTOMATIC
GAS VALVE
(with manual
shut-off valve)
FIELD
PROVIDED
AND INSTALLED
FIGURE 17
Some soaps used for leak detection are corrosive to
certain metals. Carefully rinse piping thoroughly after
leak test has been completed. Do not use matches,
candles, flame or other sources of ignition to check for
gas leaks.
Page 19
70
80
90
(21.336)
(24.384)
(27.432)
60
56
52
(1.69)
(1.58)
(1.47)
126
117
110
(3.56)
(3.31)
(3.11)
237
220
207
(6.71)
(6.23)
(5.86)
486
452
424
(13.76)
(12.79)
(12.00)
728
677
635
(20.61)
(19.17)
(17.98)
1400
1300
1220
(39.64)
(36.81)
(34.55)
2230
2080
1950
(63.14)
(58.89)
(55.22)
3950
3670
3450
(111.85)
(103.92)
(97.69)
MANUAL
MAIN SHUT-OFF
VALVE
GROUND
JOINT
UNION
DRIP LEG
Right Side Piping
(Alternate)
CAUTION
100
(30,480)
50
(1.42)
104
(2.94)
195
(5.52)
400
(11.33)
600
(17.00)
1160
(32.844)
1840
(52.10)
3260
(92.31)