Check Type
Temperature
Sensor Check
Unbalance
Check
foaming
Detected
Mems PBA
Check Detected
System Check
36 _ Troubleshooting
WW22K6800AW-A2.indb 36
Check
Mode
- The washing heater sensor in the tub has a check.
(Contact check or temperature sensor fault)
- The connector is connected incorrectly or is disconnected.
- If the water level sensor operates without water because the
TE1
water is frozen or for any other reason and the temperature
TE2
sensor engaged at the bottom to prevent overheating for the
washing heater detects a temperature of 100 to 150 ˚C, the
washing machine turns the input power off.
- The drying heater sensor in the tub has a check.
(Contact check or temperature sensor fault)
TE4
- IPM temperature is abnormally high.
- As laundry causes this check, check the laundry.
UB
- Find the reason for the unbalance and solve it as directed in
the user manual.
- This occurs when too much foaming is detected. It is also
displayed while foaming is removed. When the removal is
finished, the normal cycle proceeds.
"SUD" or "SUDS" is displayed when too much foaming is
SUD
detected and "End" is displayed when the removal of the
foaming is finished.
(This is one of the normal operations. It is a check for
preventing non-sensing faults.)
8E1
- Check detected in the Mems PBA or data check detected.
Check the wire connections.
8E2
Replace if necessary.
1. Check the wire connections.
2. Replace the Mems PBA.
8E
SF1
SF2
- Micro Controller Operation Fail.
SF3
Causes
Remarks
Heater sensor fault
: W hen the connector
is connected
incorrectly or has a
wire disconnected or
contact check
Replace Assy PCB.