Motorola AP-7522 Installation Manual page 10

Table of Contents

Advertisement

MN000879A01B.fm Page 10 Thursday, July 10, 2014 11:01 AM
10
The Motorola Access Point Power Supply (Part No. PWRS-14000-54R) is not included with the Access Point and is
orderable separately as an accessory. If the Access Point is provided both POE power and PWRS-14000-54R power
concurrently, the Access Point will source power from the PWRS-14000-54R supply only. Disconnecting the AC
power from the PWRS-14000-54R causes the Access Point to re-boot before sourcing power from the POE power
injector. If the AP is operating using injector supplied power, the AP will not automatically reboot if an AC adapter
is connected. The Access Point continues to operate with power supplied from the AC adapter without change to
the Access Point operating configuration. If using AC adapter supplied power and a change to the AP's operating
configuration is warranted, the Access Point needs to be manually rebooted by the customer.
The Access Point supports any standards-based compliant power
CAUTION
source (including non-Motorola Solutions power sources). However,
using the wrong solution (including a POE system used on a legacy
Motorola Solutions Access Point) could either limit functionality or
severely damage the Access Point and void the product warranty.
A separate Power Injector is required for each AP-7522 Access Point comprising the network.
AP-7522 Access Point

Advertisement

Table of Contents