Technical Data; Environmental Conditions And Operating Limits; Regulations For Operation With Fireplaces - Wolf FWL-ABLV AG Installation And Operating Instructions Manual

Surface-mounted housing for exhaust air fan
Table of Contents

Advertisement

Available languages

Available languages

7 Technical data

Barrier-free product, as it switches itself on and off
automatically
Not speed controllable
Electrical plug connector for quick connection of the
FWL-ABLV with housing and FWL-ABLV IB RH with
the fan insert.
Air volume – base load 30 m³/h for continuous opera-
tion
Air volume of the base load and full load levels can be
set
Additional air volumes that can be set
in base load: 20 m³/h, 40 m³/h, 60 m³/h or 100 m³/h and
in full load: 20 m³/h, 30 m³/h, 40 m³/h or 100 m³/h
Full load level on/off via light switch or separate switch.
During manual operation (e.g. using light switch), the
start delay and overrun time apply.
Full load operation (60 m³/h) with start delay of 60
seconds and overrun time of 15 minutes, non-ad-
justable
Full load operation (60 m³/h), start delay can be set with
0, 30, 60*, 90 or 120 seconds
Overrun time of the full load level can be set for 0, 3, 6,
15*, 24 or 30 minutes
Adjustable interval control for ventilating rooms that are
not regularly used. Time interval can be set for 0*, 1, 2,
4, 6 or 12 hours, 10 min. operating time per interval
Interval control can be switched off.
Switching option: The base load can be switched on or
off by an additional switch (Wiring diagrams).
* Factory setting: Tolerance of time details max. ±
5 %
*** For FWL-ABLV IB RH humidity control in full
load, 40 m³/h, 60 m³/h and 100 m³/h can be set.
7 Technical data
7.1 Environmental conditions and
operating limits
• Permissible maximum temperature of air me-
dium + 40 °C.
• The air supply to the home must be set up so
that virtually no air can flow into the living areas
from the kitchen, bathroom or WC.
• A room from which the air is to be extracted
must be fitted with a non-closable, free supply
air cross section of at least 150 cm², e.g. with
MLK door ventilation grille.
7100910 | 202201
FWL-ABLV IB
• FWL-ABLV units have resistance to interfer-
ence in line with EN 55014-2 (depending on
pulse type and an energy component of 1000 to
4000 V). These values can be exceeded when
operating with fluorescent tubes. In this case,
additional interference suppression measures
(L, C or RC modules, protection diodes, varis-
tors) are required.
7.2 Regulations for operation with
fireplaces
Sufficient supply air intake must be ensured
during operation with air-ventilated fireplaces.
The maximum permitted pressure difference per
residential unit is 4 Pa.
The unit may only be installed in residential units
with air-ventilated fireplaces under the following
conditions:
• the evaluation criteria drawn up by the respons-
ible, regional master chimney sweep are met;
FWL-ABLV AG
FWL-ABLV IB RH
●***
WOLF GmbH | 25