Connecting power and communication cable
Overall system configuration
DVM Hydro unit uses separate power supply at single phase, 220~240V.
Distribution board
Outdoor unit
ELCB
or
ELCB +
ELB
Earth
• Do not divide communication cable multiple times from one indoor/DVM Hydro unit to another. It may cause
communication error.
CAUTION
22
DVM HYDRO UNIT_IM_E_03469A(1).indd 22
ELCB
Communication cable
or
ELCB +
ELB
DVM
Hydro
unit
Exclusive
wired remote
Wired remote
controller
controller
Indoor unit
Wired remote
controller
Earth
Wired remote
controller