13. Auto white balance reference data input
Subject
White pattern standard picture frame
Adjustment Page
F
Adjustment Address
4A, 49
4C, 4B
Note 1 : Confirm that the "Camera-shaking" correction to OFF.
(TR96/TR620E/TR720E/TR740E/TR916 MODEL)
Note 2 : Confirm that the "Digital Zoom" is turned OFF.
(EXCEPT TR501E/TR503E MODEL)
Note 3 : The "Color reproduction adjustment" must have been
completed before making this adjustment.
Adjustment procedure:
Order
Page
Address
1
2
3
6
00
4
6
11
5
6
01
6
6
01
7
6
11
Processing after Adjustments:
Order
Page
Address
1
6
01
2
3
6
00
Related Adjustments:
Auto white balance adjustment
Data
Turn the main power OFF then to ON.
Shoot a white pattern with the standard picture frame.
01
After setting the data, press the PAUSE button.
Confirm that data is 00.
11
After setting the data, press the PAUSE button.
0D
After setting the data, press the PAUSE button.
(Executes the auto white balance reference data input.)
If data is 01, this is the end of data read. The data of page F,
address 49 to 4B are automatically input to this memory.
Data
00
After setting the data, press the PAUSE button.
Execute "Auto white balance adjustment".
00
After setting the data, press the PAUSE button. (End)
Procedure
Procedure
6-21