Power
Each time the heating mode is selected,
it conducts a short calibration cycle.
Airflow will be automatically controlled during
this cycle. Once the calibration cycle is complete,
it will revert to the selected airflow speed.
On first use, the appliance will default to a
temperature 3°C higher than the detected
room temperature. Thereafter, the appliance
will remember the last target temperature set.
Select the desired room temperature.
Pressing the large red button on the remote
control increases the target temperature by
1°C; the smaller red button on the remote
control decreases it by 1°C. The appliance will
not operate in heater mode unless the target
temperature is above the room temperature.
Remote control
Standby
ON/OFF
Airflow speed
control
Sleep timer
Personal
heating mode
Remote control docks magnetically.
Attach the remote control to the top of the
appliance with the buttons facing down.
10
07.07.2015 15:36 - C76365_HP01_OPMAN_CN_X264A-OPMAN UP ISSUE 06_07_15 76365.indd_15_4c0s
Heating and cool modes
Cool
mode
Thermostat
control
Oscillation
ON/OFF
Diffused
mode
To operate, point the
remote control toward
the front of the base.
Press and hold the power button to run through
the target temperatures.
Heating mode
Press the red thermostat control button until the digital
display shows the desired target temperature. The power
button light will change from blue to red. The red dot will
disappear when the target temperature has been reached
(the red circle surrounding the power button remains on
when the product is in heater mode). To adjust the airflow
speed use the airflow control button.
Cool mode
Press the blue thermostat control button to change the target
temperature to 0°C. The power button light will change
from red to blue. To adjust the airflow speed use the airflow
control button.