Internet Version for Reference Only
Venting (Part II) continued-
2" (5.1 cm) VENT PIPE LENGTHS FROM INSIDE WALL FOR LOW
GROUND CLEARANCE INSTALLATIONS
Terminating
(2) 90° Elbows with Vent Terminal
(2) 90° Elbows with Vent Terminal
(2) 90° Elbows with Vent Terminal
(2) 90° Elbows with Vent Terminal
3" (7.6 cm) VENT CONNECTOR LENGTHS FROM INSIDE WALL FOR
LOW GROUND CLEARANCE INSTALLATIONS
Terminating (Reduce 3" to 2")
(Reduce 7.6 cm to 5.1 cm)
(2) 90° Elbows with Vent Terminal
(2) 90° Elbows with Vent Terminal
(2) 90° Elbows with Vent Terminal
(2) 90° Elbows with Vent Terminal
(2) 90° Elbows with Vent Terminal
HIGH ALTITUDE INSTALLATIONS FOR ELEVATIONS OVER 2,500
FEET (610 m) ABOVE SEA LEVEL
The capacity of the induced draft blower declines with increasing altitude due to
a reduction in the air density. In order to assure safe and reliable performance
of the water heater, contact the supplier for high altitude kit.
TABLE 7
# of
Max straight
Min straight
Elbows
Length ft (m)
Length ft (m)
1
45 (13.7)
2
40 (12.2)
3
35 (10.7)
4
30 (9.2)
TABLE 8
#of
Maximum
Minimum
Elbows
Length ft (m)
Length ft (m)
1
115 (35.1)
10 (3.1)
2
110 (33.5)
10 (3.1)
3
105 (32)
10 (3.1)
4
100 (30.5)
10 (3.1)
5
95 (29)
10 (3.1)
22
2 (.6)
2 (.6)
2 (.6)
2 (.6)