Bradford White M-1-40S6BN Installation And Operating Instruction Manual page 21

Power vented gas water heater
Table of Contents

Advertisement

Internet Version for Reference Only
Venting (Part II) continued-
THROUGH THE WALL VENTING WITH LOW GROUND CLEARANCE:
When venting cannot exit through the wall at a height greater than or equal to
12" (30.5 cm) from the ground or from the anticipated snow level, then the
installation must be modified as shown below (see Figure 9). Refer to Table 7
for maximum venting lengths using 2" (5.1 cm) vent pipe or Table 8 for
maximum lengths using 3" (7.6 cm) vent pipe.
2" VENT INSTALLATION
3" VENT INSTALLATION
Figure 9
NOTE: For installations requiring both horizontal and vertical runs, the
following rule must be followed: Total length of straight pipe (both
horizontally and vertically) must not exceed the allowable length listed in
the Table 7 and 8 for total number of elbows used.
21