Installing The Rails; Overview Of The Rack Rails - Supermicro SuperServer 2029UZ-TN20R25M User Manual

Table of Contents

Advertisement

SuperServer 2029UZ-TN20R25M User's Manual

2.3 Installing the Rails

This section provides information on installing the chassis into a rack unit with the rails
provided. There are a variety of rack units on the market, which may mean that the assembly
procedure will differ slightly from the instructions provided. You should also refer to the
installation instructions that came with the rack unit you are using. Note: This rail will fit a
rack between 26.8" and 36.4" deep.

Overview of the Rack Rails

The package includes two rail assemblies. Each is specifically designed for the left or right
side of the chassis, and so marked. Each rail consists of two sections: a front section which
secures to the front post of the rack and a rear section which adjusts in length and secures
to the rear post of the rack.
Figure 2-1. Identifying the Outer Rail, Middle Rail and Inner Rail
Note: Both front chassis rails and the rack rails have a locking tab, which serves two functions.
First, it locks the server into place when installed and pushed fully into the rack (its normal
operating position. In addition, these tabs lock the server in place when fully extended from
the rack. This prevents the server from coming completely out of the rack when pulled out
for servicing.
Rail Assembly
(Shown with Rails
Retracted)
This Side Faces
Outward
(Left Rail Assembly Shown)
Outer Rail
Middle Rail
Locking Tab
20
Inner Rail

Advertisement

Table of Contents
loading

Table of Contents