▶ K5: Auto/Manual Address Setting [Applicable Only to RD***M**** Model]
S/W
K5
ON
OFF
▶ K6: Option for Snowdrift Protection Control [Common to All Models]
S/W
K6
ON
OFF
When the snowdrift protection control function is set to ON, the outdoor fan operates once for a minute every 30 minutes
when the air conditioner is running under 5 ℃.
▶ K7, K8: Setup Value Change Option for Cooling Target Evaporation Temperature [Common to All Models]
S/W
K7
K8
ON
ON
ON
OFF
OFF
ON
OFF
OFF
Please raise the setting values by improving performance while referring to the performance data of long-pipe cooling from the Technical Data Book.
In the case of short-piping, an unpleasant feeling can be felt from the low discharge air temperature of the indoor unit when the performance is raised arbitrarily.
This is an option for compensating performance in case of long-piping installation.
Please try not to use this function for other purposes.
▶ K9, K10: Silent night option. It is possible to run the unit quietly at nighttime by lowering the outdoor FAN RPM
[common to all models]
S/W
K9
K10
ON
ON
ON
OFF
OFF
ON
OFF
OFF
▶ K11, K12: Cooling Capacity Option →Use to adjust the cooling capacity. [Common to all models]
S/W
K11
K12
ON
ON
ON
OFF
OFF
ON
OFF
OFF
The cooling operation raises the frequency when the current pressure is lower than the target pressure, or in the opposite case,
lowers the frequency. When the target pressure is high, the discharge air temperature of the indoor unit increases along with an increase in energy consumption.
Display Details
Main MICOM
Version
Inverter
MICOM Version
SEG1
Indoor unit: "A"
Unit
SEG1
Indoor unit: "A"
Unit
Function (Communication Tracking)
Manually setting address of indoor unit (default)
Automatically setting address of indoor unit
Function (Snowdrift Protection Control)
No use of snowdrift protection control function (default)
Use of snowdrift protection control function
Function (Snowdrift Protection Control)
7 ~ 9 ℃ (factory shipment setting)
5 ~ 7 ℃
9 ~ 11 ℃
10 ~ 12 ℃
Function (Snowdrift Protection Control)
No use of silent night function (default)
STEP - 1
STEP - 2
STEP - 3
Function (Snowdrift Protection Control)
No adjustment for target pressure (default)
90 %
95 %
110 %
Display Value
Version (ex. 0912)
Version (ex. 0912)
Version (ex. 0912)
SEG2
Indoor unit: "0"
Address (ex:05)
SEG2
Indoor unit: "0"
Address (ex:01)
57
Applicable Model
RDSSSMSSSS series
SEG3,4
AMSSSSSMSSS
series
SEG3,4
KEY OPTION