JUnction boX Wiring (for optional bloWer)

All wiring should be done by a qualified electrician and shall
be in compliance with all local, city and state building codes.
before making the electrical connection, make sure that the
main power supply is disconnected. The fireplace, when
installed, must be electrically grounded in accordance with
local codes or, in the absence of local codes, with the National
electrical code ansi/nfpa 70 (latest edition).
A factory installed junction box is located on the lower right
side of the fireplace. Wiring must be fed to the junction box and
attached to the receptacle that is provided. Leave approximately
six
inches
of wire in the junction box for connection.
Attach black wire to one side of the receptacle and white wire to
opposite side of receptacle. The ground wire should be attached
to the green (ground) screw.
Install the receptacle into the junction box. Attach cover plate.
The fireplace can be mounted on any of the following surfaces:
1.
A flat, hard combustible (burnable) surface.
2.
A raised wooden platform.
3.
Four corner supports. (example: Four concrete masonry
blocks.) These supports must be positioned so they contact
all four perimeter edges on the bottom of the fireplace, if
allowed by local codes.
NOTICE: Verify the gas supply and electrical considerations
before beginning the framing.
framing information
Fireplace framing can be built before or after the fireplace is set
in place. Posistion framing to accommodate wall covering and
fireplace facing material. Construct the fireplace framing with
2 x 4 lumber or heavier. The framing headers or top plate may
rest on the fireplace standoffs. Refer to figure 16 for minimum
framing dimensions.
Before construction begins, measure fireplace dimensions
and verify framing methods and wall covering details.
Page 14
standard millivolt valve models
caUtion

installation

caUtion
figure 15
dimensions (in inches)
dvcd32
A
39
B
35-1/4
c
18
figure 16
dvcd36
dvcd42
39
41
38-1/4
44-1/4
18
18