Introduction - Empire Comfort Systems DVCT35CBN95N Installation Instructions Manual

Direct vent gas fireplace heater fireplace insert models
Hide thumbs Also See for DVCT35CBN95N:
Table of Contents

Advertisement

instructions to installer
1.
Leave this manual with the homeowner.
2.
Have the homeowner fill out and mail the Product
Registration Card supplied with the fireplace insert or online
at www.empirecomfort.com.
3.
Show the homeowner how to start and operate the
fireplace insert.
4.
Attach the warning label plate supplied with the insert to
the inside of the firebox of the fireplace into which the gas
fireplace insert is installed.
5.
Run fireplace insert for a minimum 30 to 35 minutes to burn
off oils from manufacturing. Failure to perform this initial
burn-off can cause pilot problems. After burn-off, clean flame
sensor on IP pilot assembly. See page 39 for sensor location.
important
Refer to complete Model Number, Serial Number and gas type
in all correspondence.
Qualified Installing Agency
Installation and replacement of gas piping, gas utilization
equipment or accessories and repair and servicing of equipment
shall be performed by a qualified agency. The term "qualified
agency" means any individual, firm, corporation or company
which either in person or through a representative is engaged
in and is responsible for (a) the installation or replacement of
gas piping or (b) the connection, installation, repair or servicing
of equipment, who is experienced in such work, familiar with all
precautions required and has complied with all the requirements
of the authority having jurisdiction.
commonwealth of Massachusetts: The installation must be
made by a licensed plumber or gas fitter in the Commonwealth
of Massachusetts.
Installation and repair should be done by a qualified service
person. The appliance should be inspected before use and at least
annually by a qualified service person. More frequent cleaning
may be required due to excessive lint from carpeting, bedding
material, etc. It is imperative that control compartments, burners
and circulating air passageways of the appliance be kept clean.
High altitude
When installing this unit at an elevation above 2000 feet (in
the United States) it may be necessary to decrease the input
rating by changing the existing burner orifice to a smaller size.
Generally, input should be reduced 4 percent for each 1000 feet
above sea level. However, if the heating value of the gas has
been reduced, this general rule may not apply. Confirm orifice
size with Empire Comfort Systems.
canadian High altitude
Altitude: 0-4500 feet (0-1370 m)
When installing this unit at an elevation above 4500 feet (in
Canada), check with local authorities.
Consult your local gas utility for assistance in determining the
proper orifice for location.
Well Head Gas installations
Some Natural Gas utilities use "well head" gas. This may affect
the Btu output of the unit and promote sooting. Units shall not be
converted to use well head gas.
Page 8

introDUction

Building codes
Consult your local building code agency, prior to installation,
to ensure compliance with local codes-including permits and
inspections.
The installation must conform with local codes or, in the
absence of local codes, with the National Fuel Gas Code
ANSI Z223.1/NFPA 54* Natural Gas and Propane Installation
Code, or CSA B149.1 in Canada. *Available from the
American National Standards Institute, Inc. 11 West 42nd
St., New York, N.Y. 10036.
The fireplace insert, when installed, must be electrically
grounded in accordance with local codes or, in absence of
local codes, with the National Electric Code ANSI/NFPA
70 or Canadian Electric code, CSA C22.1, if an external
electrical source is utilized.
preparation
This direct-vent gas fireplace insert and its components are
tested and safe when installed in accordance with this installation
manual. The fireplace insert must be installed into a wood-burning
fireplace. Report any parts damaged in shipment; specifically
check glass condition. Do not install this unit with damaged,
incomplete, or substitute parts. Read all instructions before
starting installation and follow these instructions carefully during
installation to ensure maximum benefit and safety. Failure to
follow them will void the warranty and may present a fire hazard.
This direct-vent gas fireplace insert is designed to operate with
combustion air siphoned from and all exhaust gases expelled
to the outside of the building. The information contained in this
manual pertains to all models and gas control systems listed on
the front page unless otherwise noted.
These models may be installed in a bedroom or bed-sitting room
in the U.S.A. and Canada.
Any change to this fireplace insert or its controls can be
dangerous. Improper installation or use of the fireplace
insert can cause serious injury or death from fire, burns,
explosions, or carbon monoxide poisoning.
Before enclosing the vent pipe assembly, operate the
appliance to ensure it is venting properly.
Do not operate this appliance without the glass door installed.
Due to high temperatures, the appliance must be located out
of traffic and away from furniture and draperies.
Only surrounds supplied by the manufacturer shall be used
in the installation of this appliance.
A barrier designed to reduce the risk of burns from the
hot viewing glass is provided with this appliance and shall
be installed for the protection of children and other at-risk
individuals.
If the barrier or glass front is removed during servicing or
cleaning, it must be installed prior to operating the appliance.
If the barrier becomes damaged, it must be replaced with the
manufacturer's barrier for this appliance.
Only doors certified with the appliance shall be used.
WarninG
38102-4-0319

Advertisement

Table of Contents
loading

Table of Contents