3.3

Operation

3.3.1 Display

For operation of the display and the information on it (if applicable), refer tot the instruction manual of the related
level gauge or indicator. Below, only an overview is given which display formats gives information about the
average temperature measurement.
Display format
A
C
D
3.3.2

Data items

Table 3 – 1 lists a number of data items. They contain measured data, verification data and error data. The
verification data can be used to check the results of certain steps in the measuring sequence. The temperature
status indicates the validity of the measured data. The error data provides low level error information about the
temperature measurement (refer to section 3.4).
Item
Description
AG
Measured/
AP
Calculated data
MQ
MU
U0 - UF
V0 - VF
VV
Verification data Refer to description at section 3.4.3
EM
Diagnostic data
FH
F0
Table 3 – 1
Items U0 – UD gives the position of each element with respect to the lowest part of the MRT:
st
: position of 1
element (0.25 m (9"
U0
nd
U1
: position of 2
element (0.65 m (2' 1"
rd
U2
: position of 3
element (1.25 m (4' 1"
th
U3
: position of 4
element (1.95 m (6' 4"
th
: position of 5
element (2.85 m (9' 4"
U4
th
: position of 6
element (4.15 m (13' 7"
U5
th
U6
: position of 7
element (5.65 m (18' 6"
th
U7
: position of 8
element (7.35 m (24' 1"
th
: position of 9
element (9.25 m (30' 4"
U8
th
: position of 10
U9
th
UA : position of 11
th
UB : position of 12
th
UC : position of 13
th
UD : position of 14
Items V0 – VD gives the temperature of each element:
V0
: temperature of 1
: temperature of 2
V1
|
VD : temperature of 14
Instruction manual VITO
Displayed information
Product level and average product temperature
Average gas temperature and status
Average product temperature and status
Average gas temperature
Average product temperature
Temperature status request (refer to section 3.4.2)
Measured test resistance (floating point format);
Must be: 166.5 Ω ± 0.03%
Calculated element length with respect to lowest point of MRT (see below)
Element temperatures (see below)
Error request (refer to section 3.4.1).
Fatal errors
Last fatal error
13
/
)
16
9
/
)
16
3
/
)
16
12
/
)
16
3
/
)
16
6
/
16
7
/
16
6
/
16
3
/
16
11
element (11.65 m (38' 2"
12
element (14.65 m (48' 0"
6
element (18.45 m (60' 6"
9
element (22.95 m (75' 3"
5
element (29.65 m (97' 3"
st
element
nd
element
th
element
Average temperature measurement with MRT
9
or 0.65 m (2' 1"
/
)
16
3
or 1.25 m (4' 1"
/
)
16
12
or 1.95 m (6' 4"
/
)
16
3
or 2.85 m (9' 4"
/
)
16
6
or 4.15 m (13' 7"
/
) or J4)
16
7
)
or 5.65 m (18' 6"
/
) or J5)
16
6
)
or 7.35 m (24' 1"
/
) or J6)
16
3
)
or 9.25 m (30' 4"
/
) or J7)
16
11
)
or 11.65 m (38' 2"
/
16
12
/
) or 14.65 m (48' 0"
/
16
16
6
/
) or 18.45 m (60' 6"
/
16
16
9
/
) or 22.95 m (75' 3"
/
16
16
5
/
) or 29.65 m (97' 3"
/
16
16
/
) or JD)
16
or J0)
or J1)
or J2)
or J3)
) or J8)
) or J9)
) or JA)
) or JB)
) or JC)
Page 24

Advertisement

Table of Contents
loading

Table of Contents