Inserting The Flash Memory Simm - Cisco AS5350 Installation Manual

Cisco systems universal gateway chassis installation guide
Hide thumbs Also See for AS5350:
Table of Contents

Advertisement

Appendix
Figure A-7
Caution
Some Flash memory SIMMs have the components mounted on the rear side. To prevent damage when
you insert the SIMM, always use the polarization notch as a reference, not the position of the
components on the SIMM.
Insert the new SIMM by sliding the end with the metal fingers into the appropriate SIMM socket at
Step 8
approximately a 45-degree angle to the system board as shown in Figure A-8.
Figure A-8
Gently rotate the SIMM until the latch on either side snaps into place. Do not use excessive force because
Step 9
the connector might break. When inserting the new SIMM, make sure that the polarization notch is
located at the right end of the SIMM socket.
78-10754-03 0A
Removing the Flash Memory SIMM

Inserting the Flash Memory SIMM

Cisco AS5350 Universal Gateway Chassis Installation Guide
Replacing Flash Memory SIMMs
45
-11

Advertisement

Table of Contents
loading

Table of Contents