Adjustment Procedure - Omron F3SJ-A P Series User Manual

Hide thumbs Also See for F3SJ-A P Series:
Table of Contents

Advertisement

Wiring/Installation

Adjustment Procedure

1.
Check the following points:
- The optical surface of the emitter and receiver should be clean.
- There should be no interrupting object in the detection zone of the F3SJ.
2.
Adjust the emitter's beams.
Adjust the angle of the emitter while checking the incident light level indicator, and align the emitter so
that it faces the center position where the incident light level indicator turns ON.
3.
Adjust the receiver's beams.
Adjust the angle of the receiver while checking the incident light level indicator, and align the receiver
so that it faces the center position where the incident light level indicator turns ON.
4.
Make sure that all 5 lamps of the incident light level indicator are turned ON.
5.
While taking care not to change the adjustment status of the beams, tightly fasten all the bracket
screws and mounting screws.
The table below shows the tightening torques for the included screws.
Mounting bracket type
Top/bottom mounting
brackets
Intermediate mounting
brackets
If some of the 5 lamps of the incident light level indicator are not turned ON even when the receiver angle is adjusted, check
whether or not the mounting surfaces of the emitter/receiver are parallel, and whether or not the mounting height of the emitter/
receiver is appropriate.
Tel : 03.26.04.20.21 - Fax : 03.26.04.28.20 - Web : http: www.audin.fr - Email : info@audin.fr
F3SJ-A
86
User's Manual
Nominal diameter x length of
screw (mm)
M3x8
0.54N m
M5x18
2.3N m
M3x10
0.54N m
M4x25
1.2N m
M5x10
2.3N m
AUDIN - 8, avenue de la malle - 51370 Saint Brice Courcelles