ADC HiGain H2TU-C-319 List 1E Quick Installation page 5

Hide thumbs Also See for HiGain H2TU-C-319 List 1E:

Advertisement

5
Once the H2TU-C is successfully installed and provisioned, access the Monitor or
Performance menus to clear the Performance and Alarm History screens to ensure
useful data.
L
OOPBACK
Initiate loopback testing from the HiGain HDSL2 Monitor screen or use the MODE and SEL
pushbuttons. The inband codes below can also be sent by a test set.
Network
Loopback
Inband Code
NLOC
1111000
NREM
1110000
SMJK
11000
CREM
1111110
CLOC
1111100
Loopdown 11100
For more information about the maintenance screens, refer to the H2TU-C-319 List 1E
technical practice, document number LTPH-TP-1062-xx. Contact Customer Service to
obtain a copy of the practice.
Message
(b)
PWR FEED SHRT
(b)
PWR FEED GND
(b)
PWR FEED OPEN
SPNn-LOSW
LLOS
RLOS
(c)
LAIS
(c)
RAIS
(c)
TRCI
(c)
RRAI
(c)
xxx-DBER
(c)
PRMF
(c)
PRMN
xxx-HBER
xxx-MAL
xxx-LA
(a) Front-panel alarm messages are listed in order of priority. ALRM displays prior to any alarm message.
Pressing the SEL button initiates an Alarm Cutoff (ACO) message.
(b) Message displays repeatedly as long as the alarm condition exists and is not included in the priority order.
(c) Does not activate the alarm relay access pin H.
To comply with the intrabuilding wiring requirements of
GR-1089 CORE, Section 4.5.9, the shields of the ABAM-type
cables that connect the H2TU-C-319 List 1E DSX-1 output ports
to the cross-connect panel must be grounded at both ends.
T
ESTING
H2TU-C
DSX-1
1111110
NLOC
CREM
1111000
*
When enabled, TLOS is an automatic loopback
that occurs with an LOS at the remote DS1 input.
GNLB Loopback Commands
Description
DSX-1 signal is looped back to the network at the H2TU-C.
DSX-1 signal is looped back to the network at the H2TU-R.
DSX-1 signal is looped back to the network at the H2TU-R SmartJack module.
DS1 signal from customer is looped back to the customer at the H2TU-C.
DS1 signal from customer is looped back to the customer at the H2TU-R.
Deactivates any of the above loopbacks.
Front-Panel Alarm Messages
Description
A short between the Tip and Ring of the HDSL2 pair.
The HDSL2 loop is grounded.
A line-power open condition.
The HDSL2 loop has lost synchronization. The span closest to the network has highest
priority.
No signal is detected at the DSX-1 input to the H2TU-C.
No signal is detected at the DS1 input to the H2TU-R.
Line Alarm Indication Signal.
Remote Alarm Indication Signal.
An RAI alarm (yellow LED) from the CPE with an error-free signal from the line unit or
network.
An RAI alarm (yellow LED) from the Customer Premises Equipment (CPE) with errors
from the line unit or network.
A system DS1 Bit Error Rate (BER) alarm. (xxx denotes either TUC or TUR.)
H2TU-R Performance Report Messaging BER threshold exceeded at far end.
H2TU-R Performance Report Messaging BER threshold exceeded at near end.
A system HDSL2 Block Error Rate (BER) alarm. (xxx denotes either TUC or TUR.)
The margin on the HDSL2 loop has dropped below the threshold setting. (xxx denotes
either TUC or TUR.)
The attenuation on the HDSL2 loop has exceeded the maximum threshold value. (xxx
denotes either TUC or TUR.)
H2TU-R
DS1
TLOS*
NREM
CLOC
1111100
1110000
11000
SMJK
Customer
Premises
(a)