Its; Monitor Section - Panasonic KX-FP207FX-S Service Manual

Compact plain paper fax (with digital answering system)
Table of Contents

Advertisement

6.8.
ITS (Integrated telephone System) and Monitor Section
6.8.1.
General
The general ITS operation is performed by the special IC505 which has a handset circuit. The alarm tone, the key tone, and the
beep are output from the ASIC IC501 (digital board). During the pulse dial operation, the monitor tone is output from the ASIC
IC501.
6.8.2.
Telephone Monitor (KX-FP207)
1. Function
This is the function when you are not holding the handset and can hear the caller's voice from the line.
2. Signal path
Refer to Check Sheet for Signal Route (P.123).
6.8.3.
Speakerphone Circuit (KX-FP218)
1. Function
The circuit controls the automatic switching of the transmitted and received signals, to and from the telephone line, when the
unit is used in the hands-free mode.
2. Circuit Operation
The speakerphone can only provide duplex.
3. Signal path
Refer to Check Sheet for Signal Route (P.123).
6.8.4.
Handset Circuit
1. Function
This circuit controls the conversation over the handset, i.e. the transmitted and received voices to and from the handset.
2. Signal path
Refer to Check Sheet for Signal Route (P.123).
6.8.5.
Monitor Circuit for Each Signals
1. Function
This circuit monitors various tones, such as 1 DTMF tone, 2 Alarm/Beep/Key tone/Bell.