The selection and application of Yaskawa products remain the responsibility of the equipment manufacturer or end user. Yaskawa accepts no responsibility for the way its products are incorporated into the final system design. Under no circumstances should any Yaskawa product be incorporated into any product or design as the exclusive or sole safety control.
Page 5
Yaskawa representative. ◆ Terms and Abbreviations Note: Indicates supplemental information that is not related to safety messages. Drive: Yaskawa AC Drive 1000-Series Option: Yaskawa AC Drive 1000-Series Option LONWORKS SI-W3 YASKAWA ELECTRIC TOBP C730600 56A 1000-Series Option SI-W3 Installation Guide...
Page 6
Indicates a hazardous situation, which, if not avoided, could result in death or serious injury. CAUTION Indicates a hazardous situation, which, if not avoided, could result in minor or moderate injury. NOTICE Indicates an equipment damage message. YASKAWA ELECTRIC TOBP C730600 56A 1000-Series Option SI-W3 Installation Guide...
Page 7
• When ordering new copies of the manual, contact a Yaskawa representative or the nearest Yaskawa sales office and provide the manual number shown on the front cover.
Product Overview ◆ About This Product The LONWORKS Communication Option Card (Model SI-W3) is based on LonTalk. It acts as an interface for connecting an AC drive to a LONWORKS network using the LonTalk protocol. With the option card installed to the drive, the following operations are possible with devices using the LonTalk protocol.
• A straight-edge screwdriver (blade depth: 0.4 mm, width: 2.5 mm) is required to wire the option terminal block. Note: Tools required to prepare option cables for wiring are not listed in this manual. YASKAWA ELECTRIC TOBP C730600 56A 1000-Series Option SI-W3 Installation Guide...
Refer to Option LED Display on page 12 for details on the LEDs. <2> The ground wire provided in the option shipping package must be connected during installation. Figure 1 LONWORKS Option Components YASKAWA ELECTRIC TOBP C730600 56A 1000-Series Option SI-W3 Installation Guide...
Page 11
Note: Do not turn off the power to the drive while initializing the bind data. The RUN, RX, TX, and ERR LEDs are lit (ON) during initialization of the bind data. YASKAWA ELECTRIC TOBP C730600 56A 1000-Series Option SI-W3 Installation Guide...
Page 12
The neuron ID is written on the side of the service switch. Refer to Figure 1 on page details. The bar code for the neuron ID is included on the device and the packaging. YASKAWA ELECTRIC TOBP C730600 56A 1000-Series Option SI-W3 Installation Guide...
Do not touch the drive’s main terminals and control circuit terminals when using the service switch and digital operator connector on the option unit. Failure to comply could result in death or serious injury. YASKAWA ELECTRIC TOBP C730600 56A 1000-Series Option SI-W3 Installation Guide...
Page 14
Failure to comply may prevent proper operation and possibly damage equipment. Check wiring to ensure that all connections are correct after installing the option and connecting any other devices. Failure to comply may result in damage to the option. YASKAWA ELECTRIC TOBP C730600 56A 1000-Series Option SI-W3 Installation Guide...
Page 15
E – LED label L – Connector CN5-A F – Terminal cover M – Connector CN5-B G – Removable tabs for wire routing N – Connector CN5-C Figure 2 Drive Components with Option YASKAWA ELECTRIC TOBP C730600 56A 1000-Series Option SI-W3 Installation Guide...
Page 16
NOTICE: Damage to Equipment. Observe proper electrostatic discharge procedures (ESD) when handling the option, drive, and circuit boards. Failure to comply may result in ESD damage to circuitry. Figure 3 Figure 3 Remove the Front Covers and Digital Operator YASKAWA ELECTRIC TOBP C730600 56A 1000-Series Option SI-W3 Installation Guide...
Page 17
(B) into the CN5-A connector (L) located on the drive and fasten it using one of the included screws (H). Figure 5 Figure 5 Insert the Option Card YASKAWA ELECTRIC TOBP C730600 56A 1000-Series Option SI-W3 Installation Guide...
Page 18
Select the proper type and length of communication cables. Refer to Wiring Specifications on page 22 for details on selecting cables. YASKAWA ELECTRIC TOBP C730600 56A 1000-Series Option SI-W3 Installation Guide...
Page 19
Terminal block CN1 Loosen the screws and insert the wire into the opening on the terminal block. LONWORKS drop line (do not solder ends) Figure 8 Preparing and Connecting Communication Cable Wiring YASKAWA ELECTRIC TOBP C730600 56A 1000-Series Option SI-W3 Installation Guide...
Page 20
Network SI-W3 Figure 9 Option Connection Diagram <1> Make sure the lead installed to the FE terminal on the option card is connected to the ground terminal on the drive. YASKAWA ELECTRIC TOBP C730600 56A 1000-Series Option SI-W3 Installation Guide...
Page 21
<1> <1> The drive will not meet NEMA Type 1 requirements if wiring is exposed outside the enclosure. Figure 10 Wire Routing Examples YASKAWA ELECTRIC TOBP C730600 56A 1000-Series Option SI-W3 Installation Guide...
Page 22
Refer to the Echelon web site for more information on network cabling (www.echelon.com). The performance cannot be guaranteed when using the cables other than LONWORKS network cables. Separate the LONWORKS cables from the wiring to the main circuit and other lines. YASKAWA ELECTRIC TOBP C730600 56A 1000-Series Option SI-W3 Installation Guide...
Page 23
XIF Files, Resource Files XIF files and the resource files for this option card are not included. For more information, either contact Yaskawa's sales department directly or your nearest Yaskawa representative. YASKAWA ELECTRIC TOBP C730600 56A 1000-Series Option SI-W3 Installation Guide...
Page 25
<3> Setting specifies that the torque reference or the torque limit is to be provided with Torque Reference/Torque Limit Selection from Comm. Option (F6-06 = 1). The motor might not rotate if a torque reference or a torque limit is not received from the network. YASKAWA ELECTRIC TOBP C730600 56A 1000-Series Option SI-W3 Installation Guide...
Page 27
[7] Analog [0] Analog [1] object_id Analog [2] Analog [3] Analog [4] Analog [5] Analog [6] Analog [7] Analog [8] Analog [9] Select [0] Select [1] Select [2] Select [3] YASKAWA ELECTRIC TOBP C730600 56A 1000-Series Option SI-W3 Installation Guide...
Page 29
Not supported. (Returns message: RQ_ALARM_NOTIFY_DISABLED invalid_request.) Not supported. (Returns message: RQ_MANUAL_CTRL invalid_request.) Not supported. (Returns message: RQ_REMOTE_CTRL invalid_request.) Not supported. (Returns message: RQ_PROGRAM invalid_request.) Not supported. (Returns message: 0xff RQ_NUL invalid_request.) YASKAWA ELECTRIC TOBP C730600 56A 1000-Series Option SI-W3 Installation Guide...
Page 30
Not supported. (Always 0.) bit 11 programming_mode Not supported. (Always 0.) bit 10 programming_fail Not supported. (Always 0.) bit 9 alarm_notify_disabled Not supported. (Always 0.) bit 8 to 0 reserved Always 0. YASKAWA ELECTRIC TOBP C730600 56A 1000-Series Option SI-W3 Installation Guide...
Option is damaged the option. The option Receive Heart Beat timer timed out. Connection timeout Make sure that Receive Heart Beat time is set properly. Check the option connection and communication signal. YASKAWA ELECTRIC TOBP C730600 56A 1000-Series Option SI-W3 Installation Guide...
Page 35
Option is not properly connected. Cause Possible Solution Non-compatible option connected to Use only compatible options. Connect the SI-W3 to CN5-A. For other drive port CN5-A option connections refer to the Installation Manual for those options. Digital Operator Display Fault Name...
Page 36
Only one of these options, AI-A3, DI-A3 or SI- option can be the CN5-B port while an option was connected to the drive at the same time. The SI-W3 must be connected to connected to CN5-A CN5-A. Digital Operator Display...
-20°C to +60°C (-4°F to 140°F) allowed for short-term transport of the product Area of Use Indoor (free of corrosive gas, airborne particles, etc.) Altitude 1000 m (3280 ft.) or lower YASKAWA ELECTRIC TOBP C730600 56A 1000-Series Option SI-W3 Installation Guide...
Page 38
MANUAL NO. TOBP C730600 56A QSG_only Published in Japan November 2011 11-11 Date of original publication Date of publication Date of Revision Section Revised Content Publication Number − − November 2011 First edition YASKAWA ELECTRIC TOBP C730600 56A 1000-Series Option SI-W3 Installation Guide...
Page 40
Phone: 81-3-5402-4502 Fax: 81-3-5402-4580 http://www.yaskawa.co.jp YASKAWA AMERICA, INC. 2121 Norman Drive South, Waukegan, IL 60085, U.S.A. Phone: (800) YASKAWA (927-5292) or 1-847-887-7000 Fax: 1-847-887-7310 http://www.yaskawa.com YASKAWA ELÉTRICO DO BRASIL LTDA. Avenda Fagundes Filho, 620 Bairro Saude, São Paulo, SP04304-000, Brasil Phone: 55-11-3585-1100 Fax: 55-11-5581-8795 http://www.yaskawa.com.br...
E – LED (TX) <1> L – 接地端子(取付穴) <2> F – LED (RX) <1> M – 端子台 CN1 G – ニューロン ID 表示 <1> LED の表示内容については, 「LED 表示」 (12 ページ)を参照してください。 <2> オプションカード取付時に,必ず同梱のリード線(接地用)を接続してください。 図 1 オプションカード ㈱安川電機 TOBP C730600 56A 1000 シリーズオプション SI-W3 取扱説明書...
Page 55
D – オペレータ K – インバータ側接地端子 (FE) E – LED ラベル L – 接続コネクタ CN5-A F – ターミナルカバー M – 接続コネクタ CN5-B G – ケーブル配線スペースカバー N – 接続コネクタ CN5-C (切り取り可能) 図 2 各部の名称 ㈱安川電機 TOBP C730600 56A 1000 シリーズオプション SI-W3 取扱説明書...