Download Print this page

Repair Kits - Graco 24H853 Repair Instructions

Ld oil pump repair kits

Advertisement

Repair Kits

All Repairs:
Unless otherwise stated, entirely disassemble pump
as described in the pump disassembly instruction
section of this manual.
Properly discard all replaced parts according to
local and state regulations for disposal of discarded
components.
Always use all new parts included in the kit to
replace the identical part on the pump.
Grease all parts prior to reassembly with a thin coat
of lightweight grease.
Reassemble pump as described in the reassembly
instructions, page 6.
Throat and Piston Seal Replacement Kit -
24H853 (
)
Fig. 19
NOTE: When servicing the throat and piston seals, it is
recommended to also replace seals in the pump lower.
Order repair kit: 24K293 for 3:1 pumps or 24H855 for
5:1 pumps.
Replacement parts for o-ring (5) installed on air piston
(21), o-rings and u-cup seal (6, 7, 9, and 17) installed in
bottom cover (26), o-ring (8) installed on flange (29) and
gasket (25) used later in reassembly of the air valve
(38).
O-ring (55) is installed between the air piston (21) and
displacement rod (30).
Ref.
Description
5
O-RING, air piston
6
O-RING
7
O-RING
8
O-RING, wiper
9
SEAL, u-cup
10
PIN, spring
17
O-RING
25
GASKET, cover, small
55
O-RING
3A1494D
8
25
10
Fig. 19
1. Use a pick to remove the o-ring (5) installed around
the circumference of the air piston (21) (Fig. 20).
Grease the new o-ring included in the kit and install
it around the air piston.
21
Qty
.
Fig. 20
1
1
1
2. Use a pick to remove o-rings (6, 7), bearing (22) and
1
u-cup seal (9) from the bottom cover. (Fig. 21).
1
Grease and replace the o-rings and u-cup seal with
1
the new parts included in the kit and install them in
3
the order shown in Fig. 21.
2
1
9
55
Instructions
7
5
6
17
5
9

Advertisement

loading

This manual is also suitable for:

24k29324h85524u230