Dimension Drawings - Siemens RUGGEDCOM WIN7251 Installation Manual

Table of Contents

Advertisement

Chapter 4
Technical Specifications
Overall Drain-Wire Gage
Overall Drain-Wire
Construction
Outer Jacket Material
Inner Jacket Material
Inner Jacket Diameter
External Diameter
Total Number of Wires
Standards Compliance
Flammability Rating
Standards
Performance
Frequency Range
Impedance
DC Resistance
Maximum DC Resistance
Maximum Capacitance
Unbalance
Velocity of Propagation
Maximum Propagation Delay
Skew
Dielectric Strength
Dielectric Strength to Shield
Minimum Bend Radius
Operating Temperature Range
Section 4.7

Dimension Drawings

NOTE
All dimensions are in millimeters, unless otherwise stated.
32
24 AWG
Stranded
UV resistant FR-PVC
UV resistant FR-PVC
6.1 mm (0.24 in)
8 mm (0.3 in)
8
IEC 60332, UL1581 VW-1
IEC 61156, TIA/EIA-568
1 to 100 MHz
100 Ω
93 Ω/km nominal
95 Ω/km @ 20 °C
1.6 pF/m
68% nominal
35 ns/100m
700 V/minute
700 V/minute
70 mm (2.76 in)
-40 to 70 °C (-40 to 158 °F)
RUGGEDCOM WIN7251