If the combustion air intake pipe is to be installed above a finished
ceiling or other area where dripping of condensate will be objec-
tionable, insulation of the combustion air pipe may be required.
Use 1/2" thick closed cell foam insulation such as Armaflex™ or
Insultube™ where required.
V
/F
C
ENT
LUE AND
OMBUSTION
The vent/flue and combustion air pipes may terminate vertically, as
through a roof, or horizontally, as through an outside wall.
Direct Vent (Dual Pipe) Maximum Allowable Length*
of Vent/Flue & Combustion Air Intake Pipe
(4)
Unit Input
Termination
Pipe
(Btu)
Style
(inch)
Standard
2 or 2 1/2
45,000
Alternate
2 or 2 1/2
2 or 2 1/2
Standard
3
70,000
2 or 2 1/2
Alternate
3
Standard
3
90,000
Alternate
3
Standard
3
115,000
Alternate
3
*Maximum allowable limits listed are individual lengths for inlet & flue and NOT a combination.
COUNTERFLOW
Direct Vent (Dual Pipe) Maximum Allowable Length*
of Vent/Flue & Combustion Air Intake Pipe
(4)
Unit Input
Termination
Pipe
(Btu)
Style
(inch)
2 or 2 1/2
Standard
3
70,000
2 or 2 1/2
Alternate
3
2 or 2 1/2
Standard
3
90,000
2 or 2 1/2
Alternate
3
Standard
3
115,000
Alternate
3
*Maximum allowable limits listed are individual lengths for inlet & flue and NOT a combination.
1) Elbows and/or tees used in terminations must be included when determin-
ing quantity of allowable elbows in the system.
2) Number of elbows tabulated are for each (Vent/Flue & Combustion Air
Intake) pipe.
3) Minimum requirements for each Vent/Flue & Combustion Air Intake pipe is
five (5) feet in length and one elbow/tee.
4) 2 1/2" or 3" diameter pipe can be used in place of 2" diameter pipe.
5) Increased Clearance Configurations using (2) 45 deg. Long Sweep el-
bows should be considered equivalent to one 90 deg. elbow.
Vertical pipe terminations should be as shown in the following
figure. Refer to Vent/Flue Pipe and Combustion Pipe - Termina-
tion Locations for details concerning location restrictions. The
penetrations through the roof must be sealed tight with proper
flashing such as is used with a plastic plumbing vent.
A
P
T
IR
IPE
ERMINATIONS
UPFLOW
(ft)
(1)(2)(3)(5)
Number of Elbows
1
2
3
4
5
6
71
68
65
62
59
56
58
55
52
49
46
43
49
46
43
40
37
34
71
68
65
62
59
56
36
33
30
27
24
21
57
54
51
48
45
42
71
68
65
62
59
56
57
54
51
48
45
42
49
46
43
40
37
34
35
32
29
26
23
20
(ft)
(1)(2)(3)(5)
Number of Elbows
1
2
3
4
5
6
49
46
43
40
37
34
71
68
65
62
59
56
36
33
30
27
24
21
57
54
51
48
45
42
61
58
55
52
49
46
71
68
65
62
59
56
48
45
42
39
36
33
57
54
51
48
45
42
71
68
65
62
59
56
57
54
51
48
45
42
7
8
53
50
40
37
31
28
53
50
18
15
39
36
53
50
39
36
31
28
17
14
Horizontal terminations should be as shown in the following figure.
Refer to Vent/Flue Pipe and Combustion Pipe - Termination Loca-
7
8
tion for location restrictions. A 2 3/8" diameter wall penetration is
31
28
53
50
required for 2" diameter pipe. A 3" diameter hole is required for a 2
18
15
1/2" pipe and a 3 1/2" diameter hole is required for 3" diameter
39
36
pipe. To secure the pipe passing through the wall and prohibit
43
40
damage to piping connections, a coupling should be installed on
53
50
either side of the wall and solvent cemented to a pipe connecting
30
27
the two couplings. The pipe length should be the wall thickness
39
36
plus the depth of the socket fittings to be installed on the inside
53
50
and outside of the wall. The wall penetration should be sealed with
39
36
silicone caulking material.
3" MIN
24" MAX
3" MIN
24" MAX
90º or 45°
MEDIUM RADIUS
ELBOWS
SCREEN
(OPTIONAL)
Standard Horizontal Terminations (Dual Pipe)
19
TEE (OPTIONAL)
COMBUSTION
AIR INTAKE
12" MIN.
SCREEN
(OPTIONAL)
12" MIN. TO ROOF
OR HIGHEST ANTICIPATED
SNOW LEVEL
_______________________
VENT/FLUE
12" MIN.
SCREEN
(OPTIONAL)
12" MIN. TO ROOF
OR HIGHEST ANTICIPATED
SNOW LEVEL
Vertical Terminations (Dual Pipe)
12" MIN
12" MIN. TO ROOF OR
HIGHEST ANTICIPATED
SNOW LEVEL
VENT/FLUE
12" MIN. TO ROOF OR
HIGHEST ANTICIPATED
SNOW LEVEL