Electrical Diagram Bfc - A.O. Smith 28 30 50 60 Installation & Service Manual

A. o. smith corporation service manual water products 28 30 50 60
Table of Contents

Advertisement

A
A.2
Electrical diagram
BFC
%
%
= brown
= brown
&
= blue
'
= yellow/green
(
= black
#
= white (flat ca-
$
= grey/beige
TERMINAL STRIP CONNECTIONS:
A
Earth
N
Neutral
1
L
Phase input of controller
2
L
Phase input of isolating transformer (primary side)
3
L
Phase output of isolating transformer (secondary side)
4
L
Phase input of program-controlled pump
5
L
Phase input of continuous pump
COMPONENTS:
A
Controller
B
Ionisation rod
C
Glow igniter
D
Gas control
E
Burner earth connection
F
Extra ON mode switch
G
Continuous pump
H
Program-controlled pump
J
Extra error signal
K
Isolating transformer
L
Double-pole mains switch
M
ON/OFF switch control
N
Display/Flat cable
Figure A.1 Electrical diagram BFC
92
Appendices
O
Fan
P
Temperature sensor (T2 - bottom of tank)
Q
Dummy
R
Temperature sensor (T1 - top of tank)
S
Selection resistor
T
Pressure switch
CONTROLLER CONNECTIONS:
J1
Connector for display to controller
J2
Connector for power supply to controller
J19 Connector for extra error signal
J20 Connector for gas control
J21 Connector for program-controlled pump
J24 Connector for fan
JP2 Connector for ionisation rod and glow igniter
JP3 Connector for temperature sensor T2
JP4 Connector for dummy
JP5 Connector for temperature sensor T1
JP6 Connector for selection resistor and pressure switch
JP8 Connector for extra ON mode switch
F1
Fuse
F2
Fuse
is
Instruction Manual BFC

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bfc 28Bfc 30Bfc 50Bfc 60