Introduction; Codes And Standards - International comfort products F9MVE Installation Instructions Manual

Variable speed motor, two−stage 35” tall, high efficiency condensing
Table of Contents

Advertisement

INSTALLATION INSTRUCTIONS
accessory gas conversion kit is required to convert
furnace for use with propane gas.
11.
See Table 1 for required clearances to combustible
construction.
12.
Maintain a 1−in. (25 mm) clearance from combustible
materials to supply air ductwork for a distance of 36−in.
(914 mm) horizontally from the furnace. See NFPA 90B
or local code for further requirements.
Minimum Clearances to
Table 1
Combustible Materials for All Units
POSITION
REAR
FRONT (Combustion air openings in
furnace and in structure)
Required for service
All Sides of Supply Plenum
Sides
Vent
Top of Furnace
* Consult local building codes
13.
These furnaces SHALL NOT be installed directly on
carpeting, combustible tile, or any other combustible
material other than wood flooring. In downflow
installations, factory accessory floor base MUST be
used when installed on combustible materials and wood
flooring. Special base is not required when this furnace
is installed on manufacturer's Coil Assembly or when
Coil Box is used. See Table 1 for clearance to
combustible construction information.
NOTICE
IMPORTANT
INSTALLATION
PROCEDURES
Failure to follow this procedure may result in a nuisance smoke
or odor complaint.
The manifold pressure, gas rate by meter clocking, temperature
rise and operation must be checked after installation. Minor
smoke and odor may be present temporarily after start−up from
the manufacturing process. Some occupants are more
sensitive to this minor smoke and odor. It is recommended that
doors and windows be open during the first heat cycle.

Introduction

The 4−way multipoise Category IV condensing furnace is CSA
design−certified as a direct vent (2−pipe) or non−direct vent
(1−pipe)
furnace.
(See
factory−shipped for use with natural gas. The furnace can be
converted in the field for use with propane gas when a
factory−supplied conversion kit is used. Refer to the furnace
rating plate for conversion kit information.
This furnace is not approved for installation in mobile homes,
recreational vehicles, or outdoors.
This furnace is designed for minimum continuous return−air
temperature of 60°F (15°C) db or intermittent operation down to
55°F (15°C) db such as when used with a night setback
thermostat. Return−air temperature must not exceed 80°F
(27°C) db. Failure to follow these return−air temperature limits
may affect reliability of heat exchangers, motors, and controls
(See Figure 1)
The furnace should be sized to provide 100 percent of the
design heating load requirement plus any margin that occurs
because of furnace model size capacity increments. Heating
4
CLEARANCE
In(mm)
0
1 (25)
24 (610)
*
1 (25)
*
0
0
1 (25)
AND
START−UP
Figure 3)
The
furnace
Specifications subject to change without notice.
load estimates can be made using approved methods available
from Air Conditioning Contractors of America (Manual J);
American
Society
Air−Conditioning Engineers; or other approved engineering
methods. Excessive oversizing of the furnace could cause the
furnace and/or vent to fail prematurely.
For accessory installation details, refer to the applicable
instruction literature.
NOTE: Remove all shipping materials, parts assemblies and
literature before operating the furnace.
Freeze Protection and Return Air
Figure 1
Temperature
32° F/0° C MINIMUM INSTALLED
AMBIENT OR FREEZE
PROTECTION REQUIRED

Codes and Standards

Follow all national and local codes and standards in
addition to these instructions. The installation must comply
with regulations of the serving gas supplier, local building,
heating, plumbing, and other codes. In absence of local codes,
the installation must comply with the national codes listed
below and all authorities having jurisdiction.
In the United States and Canada, follow all codes and
standards for the following:
Safety
S
US: National Fuel Gas Code (NFGC) NFPA
54−2012/ANSI Z223.1−2012 and the Installation
Standards, Warm Air Heating and Air Conditioning
Systems ANSI/NFPA 90B
is
S
A manufactured (Mobile) home installation must
conform with the Manufactured Home Construction
and Safety Standard, Title 24 CFR, Part 3280, or
when this standard is not applicable, the Standard for
Manufactured Home Installation (Manufactured Home
Sites, Communities, and Set-Ups),ANSI/NCS A225.1,
and/or CAN/CSA-Z240, MH Series Mobile Homes
S
CANADA: National Standard of Canada, Natural Gas
and Propane Installation Code (NSCNGPIC)
CAN/CSA B149.1−2010
General Installation
S
US: NFGC and the NFPA 90B. For copies, contact the
National Fire Protection Association Inc.,
Batterymarch Park, Quincy, MA 02269; or for only the
NFGC contact the American Gas Association, 400 N.
Capitol, N.W., Washington DC 20001.
Gas Furnace: (F/G)9MVE
of
Heating,
Refrigerating,
SUPPLY AIR
MAX 80°F/27°C
MIN 60°F/16°C
440 01 4400 03
and
A10490

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents