KDC-MP3036/MP3036AX/MP336/MP336AX
KDC-MP336AXS/MP336S/MP4036AX
MENU-related test mode
Press the [B.BOOST] key (main unit)
Press the [DNPP/SBF] and [DIRECT] keys (Remote control)
Backup current measurement
While ACC OFF (Back Up ON), Reset
PREOUT switching
In the STANDBY source, press and hold [AUTO] key for
1 second or longer
Fluorescent indicator (ED1) short check
In the STANDBY source, press [ATT] key
Clearing CD mechanism information / Service information / DC offset error information (Clearing E2PROM data)
Status
While pressing and holding [B.BOOST]
key and [ATT] key, reset-start.
While "– – – –" is displayed, power can be ON for 30 minutes. This mode is cancelled by resetting. (The last screen will not be retained.)
Data to be cleared is shown below.
CD mechanism information
Service Information
DC offset error information
14
Procedure
Procedure
Procedure
Procedure
Display
C
D
O
C
D
X
I2C communication status display
CD mechanism error log display
Displays CD loading error data
Displays CD EJECT error data
Displays CD time code count error data (missing count)
Displays CD time code count error data (count not updated)
Power ON time display
CD operation time display
CD EJECT times display
PANEL open/close times display
Forced Power OFF information display
DC offset error 1 display (Provides information on whether there is an improper connection or another error)
DC offset error 2 display (Provides information on the number of capacitor leaks)
TEST MODE
Continuous forwarding by remote control is prohibited
MUTE terminal is OFF after 2 seconds, not after 15 seconds.
(During this time, the CD mechanism does not function.)
Switches PREOUT
All lights are off → Turns on odd and even terminals alternatively every
125ms (terminals that have a maximum number of grids) → Turns on only
the odd terminals → Turn on only the even terminals →
At normal termination
At abnormal termination