K. Bin Control Check
1) If not already removed, remove the front panel.
2) Make sure the power switch is in the "OFF" position and that the power supply is off.
3) Remove the top panel.
4) Remove the strap connecting the spout to the chute assembly. See Fig. 18. Pull up the
chute assembly slightly so that you can access the actuator located in the top of the
chute.
5) Turn on the power supply. Make sure the control switch is in the "ICE" position, then
move the power switch to the "ON" position. WARNING! Keep hands, hair, and loose
clothing clear of the cutter on top of the evaporator assembly.
6) 30 seconds after the upper float switch closes, the control board "GM" LED turns on.
See Fig. 19. After "GM" LED turns on, press the "SERVICE" button on the control board
to bypass the 5-minute compressor delay. WARNING! Risk of electric shock. Care
should be taken not to touch live terminals.
7) "GM" LED and "COMP" LED are on. Press the actuator located in the top of the chute.
"COMP" LED and "GM" LED turn off within 10 seconds. Release the actuator.
8) Move the power switch to the "OFF" position, then turn off the power supply.
9) Replace the chute assembly and strap in their correct positions.
10) Replace the control box cover and top panel in their correct positions.
11) Turn on the power supply. Make sure the control switch is in the "ICE" position, then
move the power switch to the "ON" position to start the automatic icemaking process.
12) Replace the front panel in its correct position.
Strap
Chute Assembly
Strap
Model Shown: F-1001MAJ-C
Proximity Switch
Actuator
Spout
Control Board
Evaporator Assembly
Fig. 18
"COMP" LED
"GM" LED
33
"SERVICE" Button
F-A Control Board
Fig. 19