Smeg SR64S Manual page 15

Table of Contents

Advertisement

7.5
Referred to distance "A" in mm.
60 cm hobs with separable control panel.
Burner
Auxiliary (1)
Semirapid r (2)
Semirapid l (3)
Rapid large (4)
Ultrarapid (5)
90 cm hobs with separable control panel.
Burner
Auxiliary (1)
Semirapid (2)
Rapid (3)
Fish burner (4)
Ultrarapid (5)
60 cm hob with built-in control panel.
Burner
Auxiliary (1)
Semirapid r (2)
Semirapid l (3)
Rapid medio (4)
Ultrarapid (5)
To identify the burners on your hob, refer to the drawings in point "8.3/8.4 Arrangement of
burners on hob "
Instructions for the installer
Regulation of primary air
G20
20 mbar
3.0
1.0
1.0
1.0
1.0
G20
20 mbar
2.5
1.0
1.5
0.5
1.5
G20
20 mbar
3.0
1.0
1.0
1.5
1.0
G30/G31
28/37 mbar
4.0
2.0
2.0
3.5
5.0
G30/G31
28/37 mbar
3.0
2.0
1.5
8.0
3.0
G30/G31
28/37 mbar
4.0
2.0
2.0
3.5
4.0
41