7.3
Check that the connection has been made as described in the "Gas
connection" section.
Undo the screw "D" and push the air regulator "C" fully down. Use a
spanner to remove the nozzles "B" and fit those of suitable type
following the instructions given in the tables for bottled gas G30/G31 –
28/37 mbar. The nozzle must not be tightened to a torque of over 3 Nm.
Regulate the air flow by moving the Venturi pipe "C", until the gap "A" is
as shown in the table in point "7.5 Regulation of primary air" and fix it
with the screw "D". After making the adjustments, restore the seals
with sealing wax or an equivalent material.
Burner
Auxiliary
Semi-rapid
Rapid
Rapid large
Fish pan
Ultra rapid
Instructions for the installer
Regulation for LPG
Rated
heating
capacity
1.05
1.8
2.55
3.1
2.9
4.0
LPG – G30/G31 28/37 mbar
Nozzle
Reduced
Diameter
flowrate
1/100
(W)
mm
48
450
62
500
76
750
85
850
82
950
95
1600
Flowrate
Flowrate
g/h G30
g/h G31
76
75
131
129
185
182
225
222
211
207
291
286