Chapter 14.0 Regulatory Agency Statements

14.0 Regulatory Agency Statements

CE Compliance Statement
This Product is in Conformity with EMC Directive 2004/108/EC based on results using harmonized
standards in accordance with article 10(5), R&TTE Directive 1999/5/EC based on Following
Annex III of the directive and LVD directive 2006/95/EC based on results using Harmonized stand-
ards.
EN50131 Compliance Statement
This product meets the requirements of Class II, Grade 2 equipment as per EN50131-1:
2006+A1:2009, EN50131-3:2009, EN50131-6:2008 (Type A), EN50136-1-1:1997, EN50136-2-1,
EN50136-2-3 (ATS2) Standards. This device is suitable for use in systems with the following noti-
fication options.
-A (use of two warning devices and internal dialer required
-B (self-powered warning device and internal dialer required
-C (use of DSC compatible alternate communicator in back-up or redundant mode)
-D (use of DSC compatible alternate communicator with encryption enabled required.)
Note: For EN50131 complian installations only the intrusion portion of the alarm system has been
investigated. Fire Alarm and Auxiliary (Medical) Alarm functions were not included in the eval-
uation of this product under the requirements of the above mentioned standards.
The model HS2128, HS2064, HS2032, HS2016 Control Panel has been certified by Telefication
according to EN50131-1:2006 +A1:2009, EN50131-3:2009, EN50131-6:2008 (Type A) and
EN50136-1:1997 (ATS2) for Grade 2, Class II.
UK Compliance Statement
In the UK this product is suitable for use in systems installed to conform to PD 6662:2010 at Grade
2 and environmental class 2 with the following notification options: A, B, C, D, X
Where HS2128/HS2064/HS2032/HS2016 is used with a single path signaling method (such as the
Integrated Digital Dialer), please note the following limitation:
IMPORTANT
Your attention is drawn to the fact that failure or compromise of single path signaling cannot be
passed to the police. While the failure persists, subsequent alarms cannot be notified to the alarm
receiving centre and passed to the police.
Setting Methods
The HS2128/HS2064/HS2032/HS2016 is capable to support the completion of the full setting pro-
cedure by the following methods:
a) push button switch, mounted outside the supervised premises; or
b) protective switch (i.e., door contact) fitted to the final exit door of the alarmed premises or area.
The setting procedure is a two-stage process of initiating the setting procedure within the supervised
premises (e.g., using Mini Prox Tag (MPT) or user code) followed by completion of setting by one
of the two methods mentioned above. Please check with the Installer which method has been
enabled for your system.
Unsetting Methods
The HS2128/HS2064/HS2032/HS2016 is capable to support the following unsetting methods in
accordance with BS8243:
6.4.2 Prevention of entry to the supervised premises before the alarm system is unset. Unsetting
using remote keyfob (PG8929, PG8939, PG8949) before entering the supervised premises causes or
permits the initial entry door to be unlocked.
6.4.5 Completion of unsetting using a digital key (e.g., MPT or PG8929, PG8939, PG8949) either
before entering the protected premises (use PG8929, PG8939, PG8949) or after entering the pro-
tected premises (use MPT). The entry delay is activated if the initial entry door is opened before
the HS2128, HS2064, HS2032, HS2016 has been unset. During the entry time, it is possible to unset
- 35 -