Table 26. DD9500 with DS60 ERSO cabling instructions
String (Loop) I/O - Port
1
I/O 6 - Port 0
1
I/O 2 - Port 1
2
I/O 3 - Port 0
2
I/O 2 - Port 0
3
I/O 9 - Port 2
3
I/O 3 - Port 1
4
I/O 2 - Port 2
4
I/O 3 - Port 2
5
I/O 2 - Port 3
5
I/O 9 - Port 0
6
I/O 9 - Port 3
6
I/O 6 - Port 1
7
I/O 6 - Port 2
7
I/O 9 - Port 1
8
I/O 6 - Port 3
8
I/O 3 - Port 3
Cable lengths shown are designed for Data Domain racks. Longer cables (up to 5M) can be used.
a.
Shelf Port
A controller port 0 of shelf V1.1
B controller port 0 of the highest number shelf in V1
A controller port 0 of shelf V2.1
B controller port 0 of the highest number shelf in V2
A controller port 0 of shelf V3.1
B controller port 0 of the highest number shelf in V3
A controller port 0 of shelf V4.1
B controller port 0 of the highest number shelf in V4
A controller port 0 of shelf V5.1
B controller port 0 of the highest number shelf in V5
A controller port 0 of shelf V6.1
B controller port 0 of the highest number shelf in V6
A controller port 0 of shelf V7.1
B controller port 0 of the highest number shelf in V7
A controller HOST
port of the SSD shelf or DD Cloud Tier metadata
shelf
B controller HOST
port of the SSD shelf or DD Cloud Tier metadata
shelf
Connect Cables and Power On
a
Length
2M
2M
2M
2M
2M
5M
5M
5M
5M
5M
5M
5M
5M
5M
2M
2M