7.1 Overview
7 7 .1.4

SIMATIC memory configuration of the RF600 transponders and labels

Special memory configuration of the RF600 transponders and smartlabels
Address spaces of the transponder versions
With the RF600 readers, the user data, TID, EPC and passwords are read out via the
relevant memory banks. To read out the required data, the relevant memory bank must be
selected.
The table above shows the area and length of the user data ("USER" column). You can read
out the EPC-ID using an inventory command. As an alternative, you can also read out the
EPC-ID using a Read command to memory bank 1, start address 0x04.
Figure 7-2
Note
I I nformation on the detailed memory configuration
The memory configuration of the various transponders and smartlabels varies and depends
on the chip type used. You will find detailed information of the memory configuration in the
data sheets of the chip manufacturer.
Note
P P reset EPC ID
The EPC ID of the transponders RF620T to RF680T are preset with a 12 byte long identifier.
This identifier is based on a numbering scheme. You will find more information on this in the
section "Electronic Product Code (EPC) (Page 360)".
362
Memory configuration
System Manual, 06/2019, J31069-D0171-U001-A22-7618