E E lectrical data
Range
Impedance
Polarization
VSWR (standing wave ratio)
Power
I I nterfaces
Plug connection
M M echanical specifications
Material
Color
Tightening torque (at room temperature)
P P ermitted ambient conditions
Ambient temperature
Degree of protection
Shock resistant to EN 60068-2-27
Vibrations according to EN 60068-2-6
D D esign, dimensions and weight
Dimensions (H x W x D)
Weight
S S tandards, specifications, approvals
Proof of suitability
MTBF
1)
2)
SIMATIC RF600
System Manual, 06/2019, J31069-D0171-U001-A22-7618
During operation
During transportation and storage
The values differ for different dimensions/materials of the mounting surface.
The values for shock and vibration are maximum values and must not be applied continuously.
6.7 SIMATIC RF660A
6 6 GT2812- - 0 0 AA0x
See section "Maximum read/write ranges of
transponders (Page 59)"
50
Circular
2
2 W
RP-TNC coupling (for connection of the an-
tenna cable)
PA 12
Pastel turquoise
2 Nm
-25 ... +75 °C
-40 ... +85 °C
IP67
2)
25.5 g
1 g
2)
313 x 313 x 80 mm
1.6 kg
CE (ETSI EN 302208), FCC (Title 47, Part
15.247), cULus
228310 years
Antennas