Antennas
6.5 SIMATIC RF642A
6 6 .5.5.2

RF642A parameter assignment

Depending on the country or region in which the antenna is being operated, it is subject to
regional limitations with respect to the radiated power.
Limitations in the EU, EFTA, or Turkey
Note
L L imitation of the radiated power according to EN 302 208 V1.4.1 (ETSI)
RF600 systems that are put into operation in the EU, EFTA or Turkey must not exceed the
following radiated power with an RF642A antenna:
2000 mW ERP (or 33 dBm ERP)
Converted into EIRP: 3250 mW EIRP (or 35 dBm EIRP)
Make the following settings to ensure that the maximum permitted radiated power of the
antenna is not exceeded:
Antenna gain: 6 dBi
Radiated power:
Converted into EIRP:
Use of cable loss associated with the antenna cable.
Limitations in the USA and Canada
Note
L L imitation of the radiated power (FCC)
RF600 systems that are put into operation in the USA and Canada must not exceed the
following radiated power with an RF642A antenna:
4000 mW EIRP (or 36 dBm EIRP)
Make the following settings to ensure that the maximum permitted radiated power of the
antenna is not exceeded:
Conducted power P (dBm) of the RF600 reader: < 30 dBm
Antenna gain G
Cable loss a
P (dBm)
300
2000 mW ERP (or 33 dBm ERP)
3250 mW EIRP (or 35 dBm EIRP)
(dBi) in the FCC frequency band:
i
(dB):
1 dB
k
30 dBm - (G
- 6 dBi) + a
i
7 dBi
k