Regarding the Lamp
Removing and Installing
the Lamp Unit
Info
• Be sure to remove the lamp unit using the
handle. Be sure not to touch the glass sur-
face of the lamp unit or the inside of the
projector.
• To avoid injury to yourself and damage to
the lamp, be sure to carefully follow the
steps below.
• Do not loosen other screws except for the
filter/lamp unit cover and lamp unit.
• Please refer to the installation manual in-
cluded with the lamp unit.
1
Press
turn off the power.
• Wait until the cooling fan stops.
Warning!
• Do not remove the lamp unit from the
projector right after use. The lamp will
be very hot and may cause burn or in-
jury.
2
Disconnect the power cord.
• Unplug the power cord from the AC
socket.
• Leave the lamp until it has fully cooled
down (about 1 hour).
3
Change the air filter.
• Change the air filter whenever you in-
stall the lamp unit (see pages
54).
4
Remove the filter/lamp unit
cover.
• Turn the projector over. Loosen the user
service screw (1) that secures the fil-
ter/lamp unit cover. Pressing the tab
(2), remove the filter/lamp unit cover
(3).