louver at the desired angle.
(8) LED Display
Show the set temperature in "℃" or "℉" and the Auto-timer settings. While on DRY and FAN modes, it
shows the room temperature.
Error codes:
E1- Room temperature sensor error-Unplug the unit and plug it back in. If error repeats, call for service.
E2- Evaporator temperature sensor error- Unplug the unit and plug it back in. If error repeats, call for
service.
E3- Condenser temperature sensor error- Unplug the unit and plug it back in. If error repeats, call for
service
E4- Display panel communication error- Unplug the unit and plug it back in. If error repeats, call for service.
EC- Refrigerant leakage detection malfunction- Unplug the unit and plug it back in. If error repeats, call for
service.
P1- Bottom tray is full - Connect the drain hose and drain the collected water away. If protection repeats,
call for service.
NOTE: When more than one codes occur, the priority of the code display order is:
EC—E4—E3—E2—E1—P1
(9) FOLLOW ME/TEMP SENSING feature(optional)
NOTE: This feature can be activated from the remote control ONLY. The remote control serves as a
remote thermostat allowing for the precise temperature control at its location.
To activate the Follow Me/Temp Sensing feature, point the remote control towards the unit and press the
Follow Me/Temp Sensing button. The remote display is actual temperature at its location. The remote
control will send this signal to the air conditioner every 3 minutes interval until press the Follow Me/Temp
Sensing button again. If the unit does not receive the Follow Me /Temp Sensing signal during any 7
minutes interval, the unit will beep to indicate the Follow Me/Temp Sensing mode has ended.