Solenoid Valve Circuit
71
Ensure dip switch on PC board is in
the OFF position.
Ensure gas control wire is not loose or
damaged.
Ensure heater circuit is not grounded.
Replace PC Board.
Flame Rod
72
Check flame rod and wire for damage.
Verify HEX is not leaking.
Maintenance Indicator
FF
Placeholder in Diagnostic code history
indicating that a service provider
performed maintenance or service.
Enter this code after performing
service by pressing  (Up) , 
(Down) and On/Off simultaneously.
FF is visible on the monitor.
FF
(SS) Service Soon (Flush Heat
SS
Exchanger)
SS is a time-based service indicator
set during installation. See section
"4.12 Configure Parameter Settings"
for additional details on setting and
changing the SS indicator.
SS indicates that it is time for service.
The heat exchanger should be flushed
to prevent damage (refer to section
"6.3 Flushing the Heat Exchanger" for
more information). Hard water must
be treated to prevent scale build-up
or damage to the heat exchanger.
To reset the SS code, push the On/Off
button on the temperature controller 5
times in 5 seconds.
* See "Electrical Diagnostics" on Technical Data
Sheet located on inside front cover of water
heater.
74
NO CODE - Nothing happens when
water flow is activated
Visit rinnaipro.myabsorb.com for additional
troubleshooting resources.
Rinnai Tankless Water Heater Installation and Operation Manual
Verify you have at least the minimum
flow rate required to fire unit.
Measure the resistance or voltage of
the water flow control sensor.*
Clean inlet water supply filter.
On new installations ensure hot and
cold water lines are not reversed.