Optional Operation

Installer Setting - Setting Address of Central Control

22 Multi Type Air Conditioner
If pressing
button long for 3
1
seconds, it enters into remote
controller setter setup mode.
- If pressing once shortly, it enters
into user setup mode. Please press
more than 3 seconds for sure.
If entering into address setup mode by using
2
button, it indicates as picture below.
Set Group No. by pressing
3
button.(0~F)
Move to Indoor No. setting option
4
by pressing
Set Indoor No. by pressing
5
button.
Press
button to save.
6
Pressing
button will exit settings mode.
7
❈ After setup, it automatically gets out of
setup mode if there is no button input for
25 seconds.
❈ When exiting without pressing set button,
the manipulated value is not reflected.
Indoor No.
Group No
Function Code
button.